Range |
Resolution |
Accuracy |
Overload Protection |
40A |
10mA |
+/-1.5%+/-2dgts |
DC400A |
0-150A |
0.1A |
+/-1.5%+/-2dgts |
DC400A |
150-200A |
0.1A |
+/-1.5.5%+/-3dgts |
DC400A |
|
Range |
Resolution |
Accuracy |
Remarks |
0~9999 |
1RPM |
+/-0.5%+/-2dgts |
|
|
| AC Voltage (Autorange , Input Impedance 5M W ) |
Range |
Resolution |
Accuracy |
Overload Protection |
4V |
0.001V |
+/-1.5%+/-5dgts |
800VAC |
40V |
0.01V |
+/-1.5%+/-5dgts |
800VAC |
400V |
0.1V |
+/-1.5%+/-5dgts |
800VAC |
600V |
1V |
+/-1.5%+/-5dgts |
800VAC |
|
| DC Voltage (Autorange , Overload Protection 800VAC ) |
Range |
Resolution |
Accuracy |
Input Impedance |
400 mV |
0.1 mV |
+/-1.5%+/-3dgts |
10M W |
4V |
0.001V |
+/-1.5%+/-3dgts |
5M W |
40V |
0.01V |
+/-1.5%+/-3dgts |
5M W |
400V |
0.1V |
+/-1.5%+/-3dgts |
5M W |
600V |
1V |
+/-1.5%+/-3dgts |
5M W |
|
| Frequency (Hz, Autorange & Sensitivity selected by RANGE button) |
Range |
Resolution |
Accuracy |
Sensitivity |
Overload Protection |
100-1000kHz |
0.01-100Hz |
+/-0.5%+/-2dgts |
10 mV /0.1V/1V |
AC600V |
|
| Resistance( W )&Audible Continuity (Open Circuit Voltage 0.5V): |
Range |
Resolution |
Accuracy |
Beeper |
Overload Protection |
40-400 W |
0.1 W |
+/-1.0%+/-5dgts |
<=40 W (approx) |
AC600V |
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
|
50/60Hz |
40-400Hz |
|
40A |
10mA |
+/-1.5%+/-3dgts |
+/-2.5%+/-3dgts |
AC400A |
0-150A |
0.1A |
+/-1.5%+/-3dgts |
+/-2.5%+/-3dgts |
AC400A |
150-200A |
0.1A |
+/-2.0%+/-3dgts |
+/-3.0%+/-3dgts |
AC400A |
|
| Resistance( W )(Autorange & Manual , Open Voltage<=0.5V) |
Range |
Resolution |
Accuracy |
Overload Protection |
400 W |
0.1 W |
+/-1.5%+/-3dgts |
600VAC |
4K W |
1 W |
+/-1.5%+/-3dgts |
600VAC |
40K W |
10 W |
+/-1.5%+/-3dgts |
600VAC |
400K W |
100 W |
+/-1.5%+/-3dgts |
600VAC |
4M W |
1K W |
+/-1.5%+/-3dgts |
600VAC |
40M W |
10K W |
+/-1.5%+/-3dgts |
600VAC |
|
| Capacitance (Autorange & Manual) |
Range |
Resolution |
Accuracy |
Overload Protection |
4nF |
1pF |
+/-5.0%+/-0.2 nF |
AC600V |
40nF |
10pF |
+/-5.0%+/-0.2 nF |
AC600V |
400nF |
0.1nF |
+/-3.0%+/-0.2 nF |
AC600V |
4uF |
1nF |
+/-3.0%+/-0.2 uF |
AC600V |
40uF |
10nF |
+/-3.0%+/-0.2 uF |
AC600V |
|
| TEMP K TYPE
¢J
(Autorange & Manual,
¢K
optional): |
Range |
Resolution |
Accuracy |
Overload Protection |
-40 - 0
¢J
|
0.1
¢J
|
+/-2.0 %+/-5
¢J
|
AC600V |
0- 400
¢J
|
0.1
¢J
|
+/-0.5 %+/-1
¢J
|
AC600V |
400- 1200
¢J
|
1
¢J
|
+/-0.8 %+/-1
¢J
|
600V |
|
| Conductor Size |
23mm Diameter |
| Battery |
1.5V AA UM3 Battery x 2 |
| Display |
3 3/4Diguts(4000Counts) |
| Range Selection |
Auto and Manual |
| Power Consumption |
10mA (Approx) |
| Sampling Time |
2Time/sec (Digital) 20Time/sec (Bar graph) |
| Operating Temperature |
0
¢J
~ 50
¢J
( 32
¢K
~122
¢K
) |
| Operating Humidity |
LESS than 80% RH |
| Dimension |
7.2"(L) x 2.5"(W) x 1.4"(H)
183mm(L) x 63.6mm(W) x 35.6mm(H) |
| Weight |
190g. (Batteries Included) |
| Accessories |
Adaptor (for K-type Thermocouple and Capacitor) x 1
User Manual x 1
5V Battery x 2
K-type Thermocouple x 1
Carrying Bag x 1 |
| Option |
RPM Adaptor(COM04) x 1 |
|