Digital Multimeter

Home > Products > DC/AC Digital Multimeter > DIGITAL MULTIMETER
DIGITAL MULTIMETER
TES-2712

DIGITAL MULTIMETER

Product Features
  • Manual range with unit display
  • Inductance measurement
  • Capacitance measurement
  • Frequency measurement
  • Peak detectmeasurement

Electrical Specifications :

Accuracies aqre ± (…% of reading + …digits) at 23± 5 and below 80% RH.

DC Voltage : 

Range
Resolution
Accuracy
Input Impedance
Overload Protection
200mV
0.1mV
0.5%+1
10MΩ
600Vrms
2V
1mV
750Vpp
20V
10mV
200V
100mV
600V
1V
0.5%+2
AC Voltage : 50Hz500Hz 

Range

Resolution

Accuracy

Input Impedance

Overload Protection

200mV

0.1mV

1%+5

10MΩ

600Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

1.2%+5

DC Current : 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1%+1

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.2%+3

0.8V

20A/380V fast blow fuse
10A Continuity
20A for 30 sec. max.

AC Current : 50Hz500Hz 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1.2%+3

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.5%+3

0.8V

 20A/380V fast blow fuse

10A Continuity 
20A for 30 sec. max.
Resistance: 
Range
Resolution
Accuracy
Open Circuit Voltage
Overhead protection
200Ω
0.1Ω
0.8%+ 2
3.2V
600Vrms
2KΩ
0.5V
20KΩ
10Ω
200KΩ
100Ω
2MΩ
1KΩ
20MΩ
10KΩ
1.5%+ 3
Diode Test: ( ) 

Range

Resolution

Accuracy

Open Circuit Voltage
Text Current
Overload Protection

 

1mV

2%+ 2

3.2V

1.0mA

660Vrms

Audible Continuity:() 
 

Range

Resolution

Continuity beeper

Max Open Circuit Voltage

Overload Protection

0.1Ω

20Ω

3.2V

660Vrms

 
 
 
Frequency ( Hz )( Test Range 10Hz - 10MHz Auto Range )

Range

Resolution

Accuracy

Max. Open Circuit Voltage
Overload Protection

2KHz

1Hz

0.5%+2

1.5Vrms

600Vrms

20KHz

10Hz

200KHz

100Hz

2000Hz

1KHz

10MHz

10KHz

3Vrms

 Inductance(The accuracy is based on when “Q” value is greater than 1)

Range

Resolution

Accuracy

Test Frequency

20mH

10uH

5% + 10

200Hz

200mH

100uH

2H

1mH

20H

10mH

 
Capacitance (F)

Range

Resolution

Accuracy

Test Frequency

2000pF

1pF

3% + 10

200Hz

200nF

100pF

2uF

1nF

20uF

10nF

 
B: Peak Hold Measurement (Capture and retain elusive voltage or variant surge
                                                long enough for reading)
DC Voltage : 
Range
Resolution
Accuracy
Input Impedance
Overload Protection
200mV
0.1mV
1%+2
10MΩ
600Vrms
2V
1mV
750Vpp
20V
10mV
200V
100mV
600V
1V
AC Voltage : 50Hz500Hz 

Range

Resolution

Accuracy

Input Impedance

Overload Protection

200mV

0.1mV

1.8%+7

10MΩ

600Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

DC Current : 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1.5%+2

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.8%+2

0.8V

 

20A/380V fast blow fuse
10A Continuity
20A for 30 sec. max.
AC Current : 50Hz500Hz 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

2%+5

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

2.5%+8

0.8V

 
20A/380V fast blow fuse
10A Continuity
20A for 30 sec. max.
 
 General Specifications:
 • Numerical Display: 3-1/2 digit liquid crystal display (LCD) maximum reading 1999 and Bargraph indication.

• Palarity: Automatic “” negative polarity indication.

• Overrange: " " appears on the display.

 Sampling Rate: 2.5 readings per second.

 Power: JIS006P. 9-Volt battery, NEDA1604, IEC6F22 or JIS006P.

 Operating Storage Temperature and Humidity: 0℃ to 40℃, below 80% RH/-10℃ to 60℃, below70% RH.

• Dimensions & Weight: 180(L) x 82(W) x 38(H)mm / 365 g

• Accessories: Test leads, Spare fuse (0.5A/250V), Battery, Operating Instruction.