Multimeter

Home > Products > DC/AC Multimeter > DIGITAL MULTIMETER
TES-2712

DIGITAL MULTIMETER

Product Features
  • Manual range with unit display
  • Inductance measurement
  • Capacitance measurement
  • Frequency measurement
  • Peak detectmeasurement
DIGITAL MULTIMETER

Electrical Specifications :

Accuracies aqre ± (…% of reading + …digits) at 23± 5 and below 80% RH.

DC Voltage : 

Range
Resolution
Accuracy
Input Impedance
Overload Protection
200mV
0.1mV
0.5%+1
10MΩ
600Vrms
2V
1mV
750Vpp
20V
10mV
200V
100mV
600V
1V
0.5%+2

AC Voltage : 50Hz500Hz 

Range

Resolution

Accuracy

Input Impedance

Overload Protection

200mV

0.1mV

1%+5

10MΩ

600Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

1.2%+5

DC Current : 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1%+1

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.2%+3

0.8V

20A/380V fast blow fuse

AC Current : 50Hz500Hz 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1.2%+3

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.5%+3

0.8V

20A/380V fast blow fuse

Resistance: 

Range
Resolution
Accuracy
Open Circuit Voltage
Overhead protection
200Ω
0.1Ω
0.8%+ 2
3.2V
600Vrms
2KΩ
0.5V
20KΩ
10Ω
200KΩ
100Ω
2MΩ
1KΩ
20MΩ
10KΩ
1.5%+ 3

Diode Test: (  ) 

Range

Resolution

Accuracy

Open Circuit Voltage
Text Current
Overload Protection

 

1mV

2%+ 2

3.2V

1.0mA

660Vrms

Audible Continuity:() 

Range

Resolution

Max Open Circuit Voltage

Overload Protection

 

20Ω

3.2V

660Vrms

Frequency ( Hz )( Test Range 10Hz - 10MHz Auto Range )

Range

Resolution

Accuracy

Max. Open Circuit Voltage
Overload Protection

2KHz

1Hz

0.5%+2

1.5Vrms

600Vrms

20KHz

10Hz

200KHz

100Hz

2MHz

1KHz

10MHz

10KHz

3Vrms

 Inductance(The accuracy is based on when “Q” value is greater than 1)

Range

Resolution

Accuracy

Test Frequency

20mH

10uH

5% + 10

200Hz

200mH

100uH

2H

1mH

20H

10mH

 

Capacitance (F)

Range

Resolution

Accuracy

Test Frequency

2000pF

1PF

3% + 10

200Hz

200nF

100PF

2uF

1nF

20uF

10nF

 

B: Peak Hold Measurement (Capture and retain elusive voltage or variant surge

                                                long enough for reading)

DC Voltage : 

Range
Resolution
Accuracy
Input Impedance
Overload Protection
200mV
0.1mV
1%+2
10MΩ
600Vrms
2V
1mV
750Vpp
20V
10mV
200V
100mV
600V
1V

AC Voltage : 50Hz500Hz

 

Range

Resolution

Accuracy

Input Impedance

Overload Protection

200mV

0.1mV

1.8%+7

10MΩ

600Vrms

2V

1mV

750Vpp

20V

10mV

200V

100mV

600V

1V

DC Current : 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

1.5%+2

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

1.8%+2

0.8V

20A/380V fast blow fuse

AC Current : 50Hz500Hz 

Range

Resolution

Accuracy

Burden Voltage

Overload Protection

200uA

0.1uA

2%+5

0.35V

0.5A/250V fast blow fuse & Diode

2mA

1uA

20mA

10uA

200mA

100uA

20A

10mA

2.5%+8

0.8V

20A/380V fast blow fuse

 

General Specifications :

1.    Numerical Display : 3-1/2 digit liquid crystal display (LCD)

      maximum reading 1999 and Bargraph indication.

2.    Palarity : Automatic “ ” negative polarity indication.

3.    Overrange :  ” appears on the display.

4.    Sampling Rate : 2.5 readings per second.

5.    Power : JIS006P. 9-Volt battery, NEDA1604, IEC6F22 or JIS006P.

6.    Operating Storage Temperature and Humidity :  0°C to 40°C,

       below 80% RH / -10°C to 60°C, below 70% RH.

7.    Dimensions : 180(L) x 82(W) x 38(H)mm

8.    Weight : 365 g.

9.    Accessories : Test leads, Spare fuse (0.5A/250V), Battery,

      Operating Instruction.