- Display of Overlapped Voltage and Current Waveform
- Maximum Demand (MD in W, KW, MW) with Programmable Period
- Harmonics Analysis ( V and I ) to the 50th Order
- Display of 25 Harmonics in One Screen with Waveform
- Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles
- Analysis of Total Harmonics Distortion ( % THD-F )
- Graphic Phasor Diagram
- Programmable PT (1 to 3000) Ratios
|
- Capture 128 Transient Events ( Time + Cycles + Faults ) with Programmable Threshold(%), Can Also be Reviewed in LCD
- 50000 Records with Programmable Interval ( 1 to 6000 seconds)
- Output of Waveform, Power Parameters and 50 Harmonics at Command.
- Large Dot Matrix LCD Display with Backlight
- Optical Isolated RS-232C Interface
- Smart Datalogging to save Battery Power for Long-term Monitoring
- Built - in Calendar Clock for Data Logging
|
 |
|
| AC Watt ( 45 ~ 65 Hz, PF 0.5 to 1, CT=1 ) |
Range |
Resolution |
Accuracy of Readings |
100.0 - 999.9 W |
0.1 W |
2% ¡Ó 8 dgts |
1.000 - 9.999 KW |
0.001 KW |
2% ¡Ó 8 dgts |
10.00 - 99.99 KW |
0.01 KW |
2% ¡Ó 8 dgts |
100.0 - 999.9 KW |
0.1 KW |
2% ¡Ó 8 dgts |
1000 - 9999KW |
1 KW |
2% ¡Ó 8 dgts |
|
|
AC Current (45~65 Hz , True RMS) |
Range |
Range |
Resolution |
Accuracy of Readings |
30 - 300 A |
0.00 - 300 A |
0.1 A |
1 % of range ¡Ó 8 dgts |
300 - 999.9 A |
100.0 - 999.9 A |
0.1 A |
1 % of range ¡Ó 8 dgts |
1000 - 3000 A |
1000 - 3000 A |
1 A |
1 % of range ¡Ó 8 dgts |
|
|
Harmonics of ACA in % and Magnitude (1 to 50th order) |
Range |
Resolution |
Accuracy in % |
Resolution |
Accuracy in Magnitude |
10.0 - 300 A |
0.1 % |
¡Ó1.0% |
0.1 A |
¡Ó1.0% of range ¡Ó 0.8A |
1000 - 3000 A |
0.1 % |
¡Ó1.0% |
1 A |
¡Ó1.0% of range ¡Ó 3 A |
|
Range |
Resolution |
Accuracy of Readings |
0.00 - 1.00 |
0.01 |
¡Ó 1.5 % ¡Ó 8 digits |
|
|
Harmonics of AC Voltage in % and Magnitude
(1 to 50th order)
|
Range |
Resolution |
Accuracy in % |
Resolution |
Accuracy in Magnitude |
50 - 600 V |
0.1 % |
¡Ó0.5% |
0.1V |
¡Ó0.5 % ¡Ó 0.5V |
|
Range |
Resolution |
Accuracy of Readings |
-180 ¢X to 180 ¢X (0 ¢X to 360 ¢X ) |
0.1 ¢X |
¡Ó 1 % ¡Ó 2 digits |
|
|
AC Voltage ( 45 ~ 65 Hz, True RMS) |
Range |
Resolution |
Accuracy of Readings |
3 V - 600 V |
0.1 V |
¡Ó 0.5 % ¡Ó 5 dgts |
|
|
Total Harmonics Distortion (% THD-F , 1 to 50th order) |
Range |
Resolution |
Accuracy of Readings |
0.0 - 999.9 % |
0.1 % |
¡Ó 0.5 % ¡Ó 5 digits |
|
| Conductor Size |
150 mm (approx.) |
| Battery Type |
1.5 V SUM-3 *2 |
| Display |
128*64 Dot Matrix |
| Power Consumption |
10 mA (approx.) |
| Auto - Power - Off |
15 minutes |
| LCD update rate |
2 times/sec |
| Dimension |
130mm(L)*80mm(W)*43mm(H),
5.1"(L)*3.1"(W)*1.7"(H) |
| Accessories |
Test lead*1 pair, Users manual*1, Batteries 1.5V*2 |
| No. of Sample / Period |
512 ( V & A ), 256 (W) |
| Operating Temperature |
-10 ¢J to 50 ¢J |
| Operating Humidity |
< 85% RH |
| Storage Temperature |
-20 ¢J to 60 ¢J |
| Storage Humidity |
< 75 % RH |
| Weight |
450g |
|
|
|
TES Electrical Electronic Corp. |
- Office: 7F, No. 31, Lane 513, Rui Guang Road,
Neihu Dist., Taipei, Taiwan, R.O.C.
- TEL:886-2-2799-3660 FAX:886-2-2799-5099
- E-Mail: tes@ms9.hinet.net
|
|