PRODUCT CATALOG
- New Products
- Brix Meter
- Coating Thickness Tester
- Digital Earth Tester/Solar Power Meter
- Odor Sensing Meter/PM2.5 Air Quality Monitor & Particle Counter
- Vibration Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Thermo-Hygro-Barometer
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter/ Light Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Infrared Thermometer
- Thermometer
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Turbidity Meter/ pH/ORP/Temperature Meter
- HVAC Trms Clamp Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Weather Station/ wind speed wind volume wind direction/ Rotating speed
- Digital Multimeter
- Micro Ohmmeter
- Digital Earth Tester
- Digital Insulation Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Digital Clamp Meter
CM-03
Leakage Current Tester
Product Features
- Accurate AC digital clamp meter for leakage current measurement
- AC current measurement: 0 ~ 60A
- AC voltage measurement: 0 ~ 400V
- 10μA ultra high resolution on 40mA range
- Shield transformer jaws to minimize the effect of external stray magnetic field.
- Large jaw with 30 mm diameter.
- ACA Five Ranges (40mA, 400mA, 4A, 40A, 60A) for all application.
- A filter circuit is designed to eliminate the effect of high frequency noise and harmonics
for AC current measurement. - Large 3 3/4 digits LCD
- Fast bargraph display (30 times/sec.) for transient observation.
- Continuity and Frequency measurements.
- Max/Min, Data Hold functions, and Relative Measurement
- Easy single rotary switch for any function selection
- 600V overload protection for ohm measurement
Electrical Specifications: (23℃±5℃)
AC Current:
Range | Resolution | Accuracy | Remarks | |
50/60 Hz | Wide (40 - 1KHz) | |||
40mA | 10μA | ±1.0%±3dgts | ±2.0%±5dgts | |
400mA | 100μA | ±1.0%±3dgts | ±2.0%±5dgts | |
4A | 1mA | ±1.0%±3dgts | ±2.0%±5dgts | |
40A | 10mA | ±1.0%±3dgts | ±2.0%±5dgts | |
60A (0-50A) | 100mA | ±1.5%±3dgts | ±3.0%±5dgts | |
60A (50 - 60A)1 | 100mA | ±3.0%±5dgts | ±3.5%±5dgts |
1 Though the meter can display up to 400A, it is not calibrated beyond 60A.
AC Voltage:(Input Impedance: 10MΩ)
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
|
50/60 Hz
|
40 - 1KHz
|
|||
400V
|
0.1V
|
±1.5%±2dgts
|
±2.0%±4dgts
|
AC 800V
|
Resistance (Ω) and Continuity:(open voltage 0.4V)
Range
|
Resolution
|
Accuracy
|
Beeping
|
OL Protection
|
40-400Ω
|
0.1Ω
|
±1.0%±2dgts
|
< 38.0Ω
|
AC 600V
|
General Specifications:
Conductor Size:
|
30mm max. (approx.)
|
Battery Type:
|
two 1.5V SUM-3
|
Display:
|
3 3/4 LCD with 40 seg. bargraph
|
Range Selection:
|
manual
|
Overload Indication:
|
OL
|
Power Consumption:
|
15 mA (approx.)
|
Low battery Indication:
|
|
Sampling Time:
|
3 times/sec. (display)
30 times/sec. (bargraph)
|
Auto-Power-Off:
|
15 minutes
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Altitude:
|
up to 2000M
|
Dimension:
|
210mm (L) x 62.0mm (W) x 35.6mm (H)
8.3" (L) x 2.4" (W) x 1.4" (H)
|
Weight:
|
200g (battery included)
|
Accessories:
|
Carrying bag x 1
Users manual x 1
1.5V battery x 2
Test leads x 1
|