New Products
TES-96
Automatic ferrous / non-ferrous substrate material measurement Non-magnetic coating on ferrous metal substrate and insulating coating on non-ferrous metal substrate measurement Audible and visual warning when tolerance limits are exceeded Statistical display of significant values such as mean value, standard deviation, min, max, range Units of measurement μm/mils select Calibration curve memory, 8 for ferrous substrate and 8 for non-ferrous substrate Large LCD display with backlight Auto power off
TES-3280
TFDA Registered NO.007320 Forehead Temperature, Room Temperature, Surface Temperature measurement Applicable to Shops, Restaurants, Institutions, Schools and Homes Light and handy,Large LCD, easy to read Quick and accurate for Indoor and Outdoor measurement Fever warning function: Green, Orange and Red 3 color screen display LED light spot measurement and positioning
TES-3141T
Direct reading data via the meter, don't need via PC. Wind direction, Wind speed, Barometric pressure, Humidity and Temperature Wind rose plot Data hold & Maximum/Minimum/Average function Manual data memory and read function: 99 sets Auto data memory: microSD card USB interface APPLICATIONS HVAC Airports Agriculture Sports facility Construction Weather stations Environmental monitoring Marine and Harbour applications
TES-3250
Large LCD Display、Easy to use Check the color difference between two samples Economical, Portable and easy to use Color difference displayed Δ(L*,a*,b*), Δ(E*ab, C*ab, H*ab), Δ(Y, x, y), Δ(X, Y, Z), Δ(Rs, Gs, Bs) or Δ(WI, YI, Tw) Color space displayed (L*, a*, b*), (L*, C*ab, hab), (Y, x, y), (X, Y, Z), (Rs, Gs, Bs) or (WI, YI, Tw) Statistical function (Maximum, Minimum, Average and Standard Deviation) Color difference tolerance set to perform PASS/WARN/FAIL Store 9 color – difference target colors User calibration function ensures higher accuracy Auto memory (99 sets) & Read function Auto Power off function LCD backlight function Mini-USB interface.
TES-3145 / TES-3145U
Accuracy 1% m/s Air flow volume Instant/Avg/2/3 V max flow measurement Velocity m/s, f t/min Temperature, Humidity & Atmospheric measurement Calculate Dew point temperature, Wet bulb temperature, Wind chill temperature, Humidex temperature and Heat index temperature. LCD backlight function. Data hold & Maximum/Minimum/Average function Manual data memory and read function: 99 sets Auto data memory: 4GB microSD card (3145U) USB interface (3145U)
TES-1389 / TES-1389U
Personal dietary sugar content confirmation Food industry: Beverages, fruits and sweets Industry: Monitoring of lubricants in machines and quality control Agriculture: Determination of the degree of ripeness of fruit for quality control in harvesting Wide measuring range (Brix 0 ~ 53%) Refractive index measurement (RI) Temperature measurement (°C/°F) Ambient temperature compensation (ATC) Brix or RI high/low limit value alarm function Zero calibration with distilled or deionized water Friendly operation and easy to use Wide and dual display LCD and backlight function Reliable water resistant (IP65) Auto power off function Data memory and read function Auto data logger function (1389U) USB Interface (1389U)
TES-3196
Use a uniaxial Hall effect transverse probe with automatic temperature compensation User select Gauss, Tesla or Ampere/Meter readings DC Zero function & AC Trms measurement Data Hold & Maximum/Minimum record function Relative & Alarm High/Low limit function X, Y and Z axis vector summing function LCD backlight & auto power off function Manual memory stores up to 99 data APPLICATIONS DC magnetic field meter measuring static magnetic strength AC magnetic field meter measuring the wave motion of the electromagnetic field (EMF) After machine component are processed, remain the magnetism to measurement Magnetic force measurement of the magnetisable material Magnetic application products, the intensity of magnetic field measurement Electrical home appliances products, the magnetic field intensity measurement of the motor Exceed the leakage magnetic field of conducting the magnetite to measure Magnetic field intensity measurement of the permanent magnet Various steel products brought magnetic measurement naturally
TES-3142 / TES-3142U
Air flow volume Differential pressure, Stagnation pressure and Static pressure measurement Instant/Avg/ 2/3 V max flow measurement Velocity m/s, f t/min Temperature, Humidity & Atmospheric measurement Calculate Dew point temperature, Wet bulb temperature, Wind chill temperature, Humidex temperature and Heat index temperature. Data hold & Maximum / Minimum / Average function Manual data memory and read function: 99 sets Auto data memory: microSD card (3142U) USB interface (3142U)
TES-1386/TES-1386U
Water Quality Testing Test Tap Water Food and Beverage water Other related water quality testing Auto-ranging from 0 to 1000 NTU (Nephelometric Turbidity Unit) Waterproof and dustproof with IP65-rated housing that floats Meets performance criteria as specified by ISO 7027 (DIN EN 27027) method Low battery alarm and auto shut off after 10 minutes of non use Large LCD display and backlight function Four point calibration for full-range accuracy Maximum/minimum, alarm and relative function Manual data memory and read function Auto data logger function (1386U) USB interface (1386U)
PROVA A9+
Designed for EV (Electric Vehicle) Both lower DC Current and High DC Current(1000A) Accurate AC/DC digital clamp meter Best accuracy ±1.5%±3dgts AC 1mA, DC 10mA high resolution True RMS measurement One touch zero (Δ) for DCA adjustment 25 mm diameter jaws Fast bar graph display (30 times/sec.) for transient observation In-Rush Current Measurement with 100mS integration time Non-Contact Frequency Measurement (min. sensitivity 0.06 AC A) Non-Contact Voltage (NCV) Detection from 80V to 600V at 50/60Hz Low Pass Filter (LPF) at 1 KHz Cut-off Frequency Large 3 3/4 digits LCD Data Hold function 15 minutes auto-power-off with beeping warning before turning off Backlight with 5 minutes of auto-backlight-off Easy single rotary switch for any function selection Ideal for works in crowded switch box or cable areas
SP-500
500mm internal sphere (includes a lamp holder, baffles, and ports for photometers) Light weight and easy move APPLICATIONS: As a light collector As uniform light source Luminance/Radiance calibration Reflectance measurement (Color measurement Fluorescence spectroscopy) Beam Power measurement (total power of a beam of optical radiation) Lamp Flue measurement (total geometric luminous flux of a light source) Laser Power measurement IR Reflectance measurement Irradiance measurement (Laser, LED, and Halogen lamps)
TES-3100
Measures acceleration, Velocity and displacement RMS, EQ PEAK and EQ P-P measurement Wide range of vibration measurement by using different sensitivity of accelerometers Backlight LCD display Maximum/Minimum record function Earphone output for detecting noise in machine components Manual memory stores up to 99 data
TES-660A /TES-660
No Mic. Extension Cable required. Lightweight and small size Rechargeable battery Calculates all the popular noise dose parameters Wide dynamic range from 70 to a full 140dB Measures simultaneously 3dB, 4dB, 5dB or 6dB exchange rates Intrinsically safe (660A)
TES-1339P
Autoranging 5 steps and conversion to µmole/m²/s (PPFD: Photosynthetic Photon Flux Density). Integral illuminance measurement and conversion to mole/m²/d (Daily light integral). Luminous intensity measurement. Point - average function. User calibration factor (CAL) and spectral correction factor (SCF) function. (include LED) Time-hold function. Dual Display, 4 digit LCD reading. Spectral Sensitivity close to CIE photopic Curve. Accurate and Instant response. Data Hold function. Data memory and read function. Reference value stored for relative or percentage deviation measurement. Ripple measurement for STRAY + LIGHT function. Comparator function. Auto power off function. Auto datalogging & USB interface.
TES-5200
Particle mass & particle counter in a single handheld unit. Six mass ranges and eight particle sizes. User K-factors setting for special particulate with different densities. Integrated temperature / humidity sensor (no need for external add-on). Flow rate 2.83 L / minute (0.1 CF / minute). ‧ Rechargeable battery provides up to 4 hours of continuous operation (charge time 2.5 hours). ‧Buffer function allows storing and redisplay of up to 500 measurement data sets. ‧SD storage device.
TES-137
Dual Display, 4-digit LCD reading. Spectral Sensitivity close to CIE photopic Curve. Measuring Levels Ranging: > 0.171 to 1999k cd/m², > 0.050 to 580.0k fL, Autoranging 7 step. Accurate and Instant response. Luminance ratio A/B, deviation %A, different B-A and peak luminance measurements. User calibration factor and color-correction functions. Accumulation luminance measurement. Max/Min/AVG function. Backlight LCD display. Comparator function. Data Hold function. Data memory and read function. Data logger function. USB Interface.