Power Clamp Meter

new products
Home > Products > Power Clamp Meter
Power AC/DC Clamp Meter
TES-3063

Power AC/DC Clamp Meter

  • Communication with PC
  • 4000 Continuity Point Data Logger , 25 point manual Data Logger
  • True Power / Apparent Power / Power Factor Measurement
  • True RMS. V, A, W, cap, Ind, phase indicator
  • 4 digits with dual Display LCD
  • MIN / MAX Measurement
  • Amp / Voltage Frequency Measurement
  • PEAK HOLD Detector
  • Dual display KW + PF , KVA + PF , V+A
  • Dual display A + Hz , V + Hz
more information
Power Clamp Meter
TES-3079K

Power Clamp Meter

  • HVAC Application:
  • Check current draw in motors and compressors.
  • Use MAX/MIN/Recording in the temperature mode to assess efficiency.
  • Test run/start capacitors.
  • Confirm low voltage control signals.
  • Measure flame safeguard device current draw.
  • Confirm power sources.
  • Analyze temperature and voltage or current data with the aid of the time stamp.
  • Insulation test up to 100M Ω.



    Electrical Application:
  • Check for energized circuits and balance loads.
  • 1 Φ /3 Φ (3P3W/3P4W)Power analyzer.
  • Evaluate electrical contacts.
  • Capture motor in-rush current readings.
  • Determine peak power demand periods.
  • Verify line voltage stability.
  • Monitor motors and other loads for excess heat.
  • Check motor run/start capacitor values.
more information
3P4W POWER ANALYZER
TES-3600N

3P4W POWER ANALYZER

  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M, 3P3W3M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF,θ,Hz, &
    Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (50 sets).
  • Data Logging (4G SD CARD Memory)
  • Programmable Trigger - Points and Start / Stop Time.
  • USB Optical Interface with three phase voltage /
    current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.
more information
AC/DC Watt Clamp Meter
PROVA 400

AC/DC Watt Clamp Meter

  • AC+DC power measurement: 0 ~ 240KW
  • AC current: 0 ~ 400A (True RMS)
  • DC current: 0 ~ 400A
  • AC voltage: 0 ~ 600V (True RMS)
  • DC voltage: 0 ~ 400V
  • Frequency measurement (Auto range): 1 ~ 100K Hz
  • One touch zero for DCA adjustment
  • Large 3 3/4 digits LCD
  • Jaw diameter: 23mm
  • Fast bargraph display (30 times/sec.) for transient observation
  • Max/Min and Data Hold functions
  • Auto power off
  • Easy single rotary switch for any function selection
  • Ideal for works in crowded switch box or cable areas


more information
DC/AC CLAMP METER
PROVA 1200

DC/AC CLAMP METER

  • Accurate DC/AC digital clamp meter for current measurement.
  • 1200A AC/DC current measurement
  • Analog Output for datalogger or oscilloscope.
  • One touch zero for DCA adjustment.
  • 23mm diameter jaw.
  • Integrated current probe for waveform observation or recording
  • Large 3 3/4 digits LCD
  • Fast bargraph display (30 times/sec.) for transient observation.
  • Max/Min and Data Hold functions.
  • Easy single rotary switch for any function selection.
  • Ideal for works in crowded switch box or cable areas.
more information
3 Φ Power Clamp
PROVA-6600

3 Φ Power Clamp

  • 3*4W, 3*3W, 3* balanced, 1*2W and 1*3W power measurement
  • AC+DC true power: 0 ~ 1200KW (AC 600V, DC 800V, ACA/DCA 2000A)
  • AC+DC voltage (True RMS): 0 ~ 600V
  • AC+DC current (True RMS): 0 ~ 2000A
  • AC+DC 1200KW(1*), AC+DC 2000KW (3*)
  • Dual display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
  • Phase angle measurement
  • Frequency measurement
  • 3* RST(L1L2L3) Sequence Indication
  • Memory of 4 records
  • DCA/DCW auto zero when power clamp powering on
  • AC/DC auto detection
  • Auto range
  • Jaw diameter: 55mm
  • Low battery indication
more information
3 Φ PF Power Clamp
PROVA-6601

3 Φ PF Power Clamp

  • 3-phase (4W, 3W) and 1-phase (2W, 3W) power measurement
  • AC+DC true power: 0 ~ 1200KW (AC 600V, DC 800V, ACA/DCA 2000A)
  • AC+DC voltage (True RMS): 0 ~ 600V
  • AC+DC current (True RMS): 0 ~ 2000A
  • AC+DC 1200KW (1-phase), AC+DC 2000KW (3-phase)
  • Dual display V+Hz, A+V, W+PF, KVA+KVAR
  • PF for 3-phase (4W, 3W) and 1-phase (2W)
  • Frequency measurement
  • Memory of 4 records
  • AC/DC auto detection
  • Auto range
  • Jaw diameter: 55mm
  • Low battery indication
more information
TRMS Power Analyzer
WM-01/03

TRMS Power Analyzer

  • Easy plug-in and test
  • 4 LCD displays of W, PF/VA, V/KHz, A
  • True power/ watt, True RMS V, A
  • Auto range of W and V
  • AC/DC 200W/2000W auto range
  • Light and portable
  • Battery powered / AC adapter
  • Frequency measurement
  • Max Hold and Data Hold.
  • RS-232 computer interface
  • Ready_To_Use WindowTM Application Software
  • Software calculates the require capacitance to improve PF
  • Direct display of Power Factor (PF)
  • Datalogging of 1012 sets of records (WM-03)

    Applications:
  • Power device research and development
  • Production Q.C. (eg. Home appliance)
  • Field maintenance
  • Power distribution management
  • Education and experiment
more information
Specification changes subject without notice.