Flexible Clamp Meter

Home > Products > DC/AC Flexible Clamp Meter > Flexible Power Quality Tester
AFLEX-3005

Flexible Power Quality Tester

Product Features
  • AC current measurement up to 3000A (True RMS): basic accuracy 1% of range
  • AC voltage measurement up to 600V (True RMS): basic accuracy 0.5% of range
  • AC watt measurement up to 9999KW: basic accuracy 1% of range
  • Power quality analysis for single and balanced 3 phase system
  • Measurement of balanced 3Φ power quality and phase sequence
  • Active (W, KW, HP), Reactive (VAR, KVAR) and Apparent (VA, KVA) power
  • Power factor (PF), Phase angle (Φ), and Energy (WH, KWH)
  • 1 to 50th order of harmonics at 2.0% basic accuracy
  • Total harmonic distortion (%THD-F) and Crest factor (CF)
  • Frequency of ACV or ACA: 45 ~ 65 Hz
  • Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
  • Work with PC via USB interface
  • Programmable CT ratio from 1 to 250
  • Max / Min / Data Hold functions
  • Auto power off function in 30 minutes
  • Data logging memory size: 8000 records
Flexible Power Quality Tester

Electrical Specifications: (23±5)

AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1, V>AC 5V, Current>AC 5A for A range)

      Range

(5 to 3000A)

Resolution

Accuracy of Readings

> 20 V and > 30A

< 20V or < 30A

10.0 – 999.9 W

0.1W

±1% of range

±2% of range

1.000 – 9.999 KW

0.001 KW

±1% of range

±2% of range

10.00 – 99.99 KW

0.01 KW

±1% of range

±2% of range

100.0 – 999.9 KW

0.1 KW

±1% of range

±2% of range

1000 – 9999 KW

1 KW

±1% of range

±2% of range

  

AC Apparent Power (VA, from 0.000VA to 9999 KVA)

Range

(5 to 3000A)

Resolution

Accuracy of Readings

> 20 V and > 30A

< 20V or < 30A

10.0 – 999.9 VA

0.1VA

±1% of range

±2% of range

1.000 – 9.999 KVA

0.001 KVA

±1% of range

±2% of range

10.00 – 99.99 KVA

0.01 KVA

±1% of range

±2% of range

100.0 – 999.9 KVA

0.1 KVA

±1% of range

±2% of range

1000 – 9999 KVA

1 KVA

±1% of range

±2% of range

 

AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR)

Range

(5 to 3000A)

Resolution

Accuracy of Readings

> 20 V and > 30A

< 20V or < 30A

10.0 – 999.9 VAR

0.1VAR

±1% of range

±2% of range

1.000 – 9.999 KVAR

0.001 KVAR

±1% of range

±2% of range

10.00 – 99.99 KVAR

0.01 KVAR

±1% of range

±2% of range

100.0 – 999.9 KVAR

0.1 KVAR

±1% of range

±2% of range

1000 – 9999 KVAR

1 KVAR

±1% of range

±2% of range

 

Power Factor (PF)

Range

Resolution

Accuracy

> 20V and > 30A

< 20V or < 30A

0.000 – 1.000

0.001

± 0.04

±0.1

 

AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4, CT=1)

Range

Resolution

Accuracy of Readings

5.0 – 300.0A

0.1A

±1% of range

300.0 – 999.9A

0.1A

±1% of range

1000 – 3000 A

1 A

±1% of range

 

AC Voltage (50/60 Hz, Auto Range, TRMS, C.F.<4, Overload Protection AC 800V)

Range

Resolution

Accuracy of Readings

4.0 V – 600.0 V

0.1 V

±0.5% ± 5dgts

 

Harmonics of AC Voltage in Percentage

Range

Resolution

Accuracy

1 – 20th

0.1%

±2%

21 – 50th

0.1%

4% of reading ± 20dgts

 

Harmonics of AC Voltage in Magnitude

Range

Resolution

Accuracy

1 – 20th

0.1V

±2% ± 0.5V

21 – 50th

0.1V

4% of reading ±0.5V

 

Harmonics of AC Current in Percentage

Range

Resolution

Accuracy

1 – 20th

0.1%

±2%

21 – 50th

0.1%

4% of reading ± 20dgts

 

Harmonics of AC Current in Magnitude (True RMS300A)

Range (5 – 300A)

Resolution

Accuracy

1 – 20th

0.1A

±2% of reading ±0.4A

21 – 50th

0.1A

±4% of reading ±0.4A

 

Harmonics of AC Current in Magnitude (3000ATrue RMS300A)

Range

Resolution

Accuracy

1 – 20th

0.1A

±2% of reading ±40A

21 – 50th

0.1A

±4% of reading ±40A

 

Phase Angle (Φ, V > 20V, A > 30A)

Range

Resolution

Accuracy

-180° to 180°

0.1°

± 1°

0° to 360°

0.1°

± 1°

 

Total Harmonic Distortion

Range

Resolution

Accuracy

0.0 – 20%

0.1%

± 2%

20 – 100%

0.1%

± 6% of reading ± 1%

100 – 999.9 %

0.1%

± 10% of reading ± 1%

 

Peak Value of AC Voltage (RMS value > 10V) or AC Current (RMS value > 30A)

Range

Sampling Time

Accuracy of Reading

50 Hz

39 μs

± 5% ± 30 digits

60 Hz

33 μs

± 5% ± 30 digits

 

Crest Factor (C.F.) of ACV (RMS value > 10V) or ACA (RMS value > 30A)

Range

Resolution

Accuracy of Readings

1.00 – 99.99

0.01

± 5% ± 30 digits

 

Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)

Range

Resolution

Accuracy

45 – 65

0.1

± 0.2Hz

 General Specifications:

Probe Length: 3005-24  

24 in / 610 mm

Minimum Bending Diameter:  

35mm

Connector Diameter:

23mm

Cable Diameter:

14mm

Cable Length from Probe to Box:

1700mm

Cable Length from Box to Output:

1700mm

Dimension (Box):

130mm(L) x 80mm(W)x 43mm(H)

5.1”(L) x 3.1”(W) x 1.7”(H)

Battery Type:

two 1.5V SUM-3

Battery life:

200hrs @ 2000mAH.

Display:

4+4 digits LCD

Range Selection:

Auto

Overload Indication:       

OL

Power Consumption:      

10mA(approx.)

Low battery Indication:

Auto-Power-Off:

30 minutes after power-on

LCD Update Time:

2 times/sec.

No. Of Samples per Period

512 (voltage or current)

256 (power)

Data logging memory size:

8000 records

Data logging sampling time:

0~600 sec

Data logging period:      

8000 x sampling time (0~600 sec.)

Operating Temperature: 

5°C to 50°C

Operating Humidity:

15% to 85% RH

Altitude:

up to 2000M

Storage Temperature:

-20°C to 60°C

Storage Humidity:

15% to 85% RH

Weight:

430g (battery included)

Accessories:

Test leads

Carrying case x 1

Users manual x 1

Batteries 1.5V x 2

Software CD x 1