Sound Level/Vibration Meter

TES-3100 / TES-3101 / TES-3102

VIBRATION METER

Product Features
  • Measures acceleration, Velocity and displacement
  • RMS, EQ PEAK and EQ P-P measurement
  • Wide range of vibration measurement
  • Using different sensitivity of accelerometers
  • Maximum/Minimum record function
  • USB interface allows transfer of saved data to PC (3101, 3102)
  • Manual memory stores up to 100 data
  • Auto memory micro SD card 4GB (3101, 3102)
  • Earphone output for detecting noise in machine components
VIBRATION METER

 

Piezoelectric Accelerometer PA-01  (3100, 3101, 3102)

Sensitivity

5mV/(m/s²)(±10%)

Acceleration range

100 g pk(980m/s²)

Amplitude nonlinerity

<=5%

Freqency response

10Hz to 1kHz (±10%), 1kHz to 15kHz (±3dB)

Resonance freqency

>=15 kHz

Transverse sensitivity

<=5%

Dimensoins/Weight

46(H) x 17(D) mm / 45 g

Piezoelectric Accelerometer PA-02  (3102)

Sensitivity

10mV/(m/s²)(±10%)

Acceleration range

50 g pk(490m/s²)

Amplitude nonlinerity

<=2%

Freqency response

10Hz to 1kHz (±10%), 1kHz to 10kHz (±3dB)

Resonance freqency

>=15 kHz

Transverse sensitivity

<=5%

Dimensoins/Weight

50(H) x 20(D) mm / 78 g

Measurement range (using PA-01 or PA-02)

ACC (Acceleration)

0.02 to 200m/s²        EQ PEAK  1Hz to 5kHz

VEL (Velocity)

0.3 to 1000mm/s      RMS          3Hz to 1kHz

0.1 to 1000mm/s      RMS          10Hz to 1kHz

DISP (Displacement)

0.02 to 100mm         EQ PEAK  3Hz to 500Hz

0.001 to 100mm       EQ PEAK  10Hz to 500Hz

Frequency range

ACC (Acceleration)

3Hz to 1kHz, 3Hz to 5kHz, 1Hz to 100Hz, 3Hz to 20kHz

VEL (Velocity)

10Hz to 1kHz, 3Hz to 1kHz

DISP (Displacement)

1Hz to 500Hz, 3Hz to 500Hz

Measurement full-scale range

For accelerometer PA-01 and accelerometers with sensitivity

1.0 to 9.9mV/(m/s²)

ACC (Acceleration)

1, 10, 100, 1000m/s²

VEL (Velocity)

10, 100, 1000mm/s

DISP (Displacement)

0.1, 1, 10, 100mm

Indication characteristics

Acceleration

RMS, EQ PEAK

Velocity

RMS, EQ PEAK

Displacement

RMS, EQ PEAK, EQ p-p

Gain calibration (Accelerometer sensitivity selection establishes suitable gain)

Setting range

0.10 to 0.99, 1.0 to 9.9, 10 to 99mV (m/s²)

Ambient conditions for operation

Accelerometer

-20 to +70℃, max. 90%RH

Main unit

-10 to +50℃, max. 90%RH

Manual memory

Maximum 100 data can be stored manually

Auto memory   (3101, 3102)

Micro SD CARD 4GB

Power requirements

4 IEC R6 (size AA) batteries, AC adapter 6V (option)

Battery life (continuous use)

8 hours (approx.)

Dimensions / Weight

155(L) × 78(W) × 40(H)mm

Supplied accessories

Instruction manual, Battery,(CD software, Micro-USB cable) â (3101, 3102)