Vibration Meter

Home > Products > DC/AC Vibration Meter > VIBRATION METER
VIBRATION METER
TES-3101

VIBRATION METER

Product Features
  • Measures acceleration, Velocity and displacement
  • RMS, EQ PEAK and EQ P-P measurement
  • Wide range of vibration measurement by using different sensitivity of accelerometers
  • Backlight LCD display
  • Auto memory micro SD card , USB interface to PC
  • Earphone output for detecting noise in machine components
  • Excellent accelerometer for harsh environments
  • Maximum/Minimum record function
  • Manual memory stores up to 99 data
ISO 2372  Equipment vibration standard
Equipment category
Good
Acceptable
Still permissible
Dangerous
15KW the following small machinery and equipment
0 ~ 0.71 mm/s
0.72 ~ 1.80 mm/s
1.81 ~ 4.5 mm/s
> 4.5  mm/s
15KW-75KW medium-sized machinery and quipment
0 ~ 1.12 mm/s
1.13 ~ 2.80 mm/s
2.81 ~ 7.1 mm/s
> 7.1  mm/s
Large machinery and equipment
0 ~ 1.80 mm/s
1.81 ~ 4.50 mm/s
4.51 ~ 11.2 mm/s
> 11.2 mm/s
Large / large mechanical equipment
0 ~ 2.80 mm/s
2.81 ~ 7.10 mm/s
7.11 ~ 18.0 mm/s
> 18   mm/s

 SPECIFICATIONS 

Piezoelectric Accelerometer (PA-01)
Sensitivity
5mV/(m/s²)(±10%)
Acceleration range
200m/s²
Amplitude nonlinearity
±1%
Frequency response
5Hz to 10kHz (±10%), 10kHz to 15kHz (±3dB)
Resonance frequency
27kHz
Transverse sensitivity
5%
Dimensions/Weight
46(H) x 19(D) mm / 46g
Measurement range (PA-01)
ACC (Acceleration)
0.02 to 200m/s²        EQ PEAK  1Hz to 5kHz
VEL (Velocity)
0.3 to 1000mm/s      RMS          3Hz to 1kHz
0.1 to 1000mm/s      RMS          10Hz to 1kHz
DISP (Displacement)
0.02 to 100mm         EQ PEAK  3Hz to 500Hz
0.001 to 100mm       EQ PEAK  10Hz to 500Hz
Frequency range
ACC (Acceleration)
3Hz to 1kHz, 3Hz to 5kHz, 1Hz to 100Hz, 3Hz to 20kHz
VEL (Velocity)
10Hz to 1kHz, 3Hz to 1kHz
DISP (Displacement)
1Hz to 500Hz, 3Hz to 500Hz
Measurement full-scale range
For accelerometer PA-01 and accelerometers with sensitivity
1.0 to 9.9mV/(m/s²)
ACC (Acceleration)
1, 10, 100, 1000m/s²
VEL (Velocity)
10, 100, 1000mm/s
DISP (Displacement)
0.1, 1, 10, 100mm
Indication characteristics
Acceleration
RMS, EQ PEAK
Velocity
RMS, EQ PEAK
Displacement
RMS, EQ PEAK, EQ p-p
Gain calibration (Accelerometer sensitivity selection establishes suitable gain)
Setting range
0.10 to 0.99, 1.0 to 9.9, 10 to 99mV (m/s²)
Ambient conditions for operation
Accelerometer
-20 to +70°C, max. 90%RH
Main unit
-10 to +50°C, max. 90%RH
Manual memory
Maximum 99 data can be stored manually
Auto memory   
Micro SD CARD 
Power requirements
4 IEC R6 (size AA) batteries, AC adapter 6V (option)
Battery life (continuous use)
8 hours (approx.)
Dimensions / Weight
158(L) × 78(W) × 40(H)mm / 286g
Supplied accessories
Instruction manual, Battery,CD software, Micro-USB cable