PRODUCT CATALOG
- 
	New Products 
	 
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Multimeter
- Insulation Tester
- Earth Tester
- Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Vibration Meter
TES-3101
VIBRATION METER
Product Features
- Measures acceleration, Velocity and displacement
- RMS, EQ PEAK and EQ P-P measurement
- Wide range of vibration measurement by using different sensitivity of accelerometers
- Backlight LCD display
- Auto memory micro SD card , USB interface to PC
- Earphone output for detecting noise in machine components
- Excellent accelerometer for harsh environments
- Maximum/Minimum record function
- Manual memory stores up to 99 data
| ISO 2372  Equipment vibration standard | ||||
| Equipment category | Good | Acceptable | Still permissible | Dangerous | 
| 15KW the following small machinery and equipment | 0 ~ 0.71 mm/s | 0.72 ~ 1.80 mm/s | 1.81 ~ 4.5 mm/s | > 4.5  mm/s | 
| 15KW-75KW medium-sized machinery and quipment | 0 ~ 1.12 mm/s | 1.13 ~ 2.80 mm/s | 2.81 ~ 7.1 mm/s | > 7.1  mm/s | 
| Large machinery and equipment | 0 ~ 1.80 mm/s | 1.81 ~ 4.50 mm/s | 4.51 ~ 11.2 mm/s | > 11.2 mm/s | 
| Large / large mechanical equipment | 0 ~ 2.80 mm/s | 2.81 ~ 7.10 mm/s | 7.11 ~ 18.0 mm/s | > 18   mm/s | 
SPECIFICATIONS
| Piezoelectric Accelerometer (PA-01) | |
| Sensitivity | 5mV/(m/s²)(±10%)  | 
| Acceleration range | 200m/s² | 
| Amplitude nonlinearity | ±1% | 
| Frequency response | 5Hz to 10kHz (±10%), 10kHz to 15kHz (±3dB) | 
| Resonance frequency | 27kHz | 
| Transverse sensitivity | ≦5% | 
| Dimensions/Weight | 46(H) x 19(D) mm / 46g | 
| Measurement range (PA-01) | |
| ACC (Acceleration) | 0.02 to 200m/s²        EQ PEAK  1Hz to 5kHz | 
| VEL (Velocity) | 0.3 to 1000mm/s      RMS          3Hz to 1kHz  0.1 to 1000mm/s      RMS          10Hz to 1kHz | 
| DISP (Displacement) | 0.02 to 100mm         EQ PEAK  3Hz to 500Hz 0.001 to 100mm       EQ PEAK  10Hz to 500Hz | 
| Frequency range | |
| ACC (Acceleration) | 3Hz to 1kHz, 3Hz to 5kHz, 1Hz to 100Hz, 3Hz to 20kHz | 
| VEL (Velocity) | 10Hz to 1kHz, 3Hz to 1kHz | 
| DISP (Displacement) | 1Hz to 500Hz, 3Hz to 500Hz | 
| Measurement full-scale range | |
| For accelerometer PA-01 and accelerometers with sensitivity | 1.0 to 9.9mV/(m/s²) | 
| ACC (Acceleration) | 1, 10, 100, 1000m/s² | 
| VEL (Velocity) | 10, 100, 1000mm/s | 
| DISP (Displacement) | 0.1, 1, 10, 100mm | 
| Indication characteristics | |
| Acceleration | RMS, EQ PEAK | 
| Velocity | RMS, EQ PEAK | 
| Displacement | RMS, EQ PEAK, EQ p-p | 
| Gain calibration (Accelerometer sensitivity selection establishes suitable gain) | |
| Setting range | 0.10 to 0.99, 1.0 to 9.9, 10 to 99mV (m/s²) | 
| Ambient conditions for operation | |
| Accelerometer | -20 to +70°C, max. 90%RH | 
| Main unit | -10 to +50°C, max. 90%RH | 
| Manual memory | Maximum 99 data can be stored manually | 
| Auto memory    | Micro SD CARD  | 
| Power requirements | 4 IEC R6 (size AA) batteries, AC adapter 6V (option) | 
| Battery life (continuous use) | 8 hours (approx.) | 
| Dimensions / Weight | 158(L) × 78(W) × 40(H)mm / 286g | 
| Supplied accessories | Instruction manual, Battery,CD software, Micro-USB cable | 
 Video
Video

 
			 
			