Clamp Meter

Home > Products > DC/AC Clamp Meter > Digital AC Clamp Meter
Digital AC Clamp Meter
Digital AC Clamp Meter
TES-3040H

Digital AC Clamp Meter

Product Features
  • 3-3/4 Digital LCD with bar-graph
  • Auto-Ranging on Volt, Ohm, Current, Frequency measurements
  • Auto-power off
  • Data Hold mode
  • MAX/MIN Hold mode
  • Zero Adjustment/Relative Reading

 MEASUREMENT SPECIFICATIONS:

 AC Current (Autorange & Manual): Low Pass Filter 

Range
Resolution
Accuracy
Overload protection
Frequency
Response
400A
0.1A
±(2% + 10)
1100A
40~450 Hz
1000A
1A

 Conversion type: AC coupled, TRMS measurement.

 Additional Crest Factor Errors (non - sinecure) 

Crest Factor

Error (% of reading)

1 - 3

0.5%

3 - 5

3%

5 - 7

6%

 Response time: 5 seconds max, to rated accuracy within selected range.  

INFLUENCE OUANTITY 

Influence quantity

Limits of variation

Measured quantity

Tolerance

Position of conductor in the clamp conductor’s diameter: 20mm

In relation to the center

Amps

±(1%+5)

  DC Voltage (Autorange & Manual) 

Range

Resolution

Accuracy

Input Impedance

Overload protection

400mV

0.1mV

±(0.75% + 2)

≒ 11MΩ

600Vrms

4V

0.001V

≒ 10MΩ

40V

0.01V

400V

0.1V

600V

1V

 Response time: 3 seconds max. to rated accuracy within selected range.

 AC Voltage (Autorange & Manual): Low Pass Filter 

Range

Resolution

Accuracy

Input impedance

Overload protection

Frequency

Response

4V

0.001V

±(1.2%+5)

≒ 11MΩ

600Vrms

40~450 Hz

40V

0.01V

≒ 10MΩ

400V

0.1V

600V

1V

±(1.5%+5)

 Conversion type: AC coupled, TRMS measurement. 

Additional Crest Factor Errors (non - sinecure) 

Crest Factor

Error (% of reading)

1 - 3

0.5%

3 - 5

3%

5 - 7

6%

 Response time: 5 seconds max, to rated accuracy within selected range.

 Frequency (Hz) (Autorange for Voltage) 

Range

Resolution

Accuracy

Sensitivity

Overload protection

100Hz

0.01Hz

±(0.1% + 2)

100mV

600Vrms

1KHz

0.1Hz

5KHz

0.001KHz

 

Frequency (Hz) (Autorange for Current) 

Range
Resolution
Accuracy
Sensitivity
Overload protection
100Hz
0.01Hz
±(0.5% + 5)
5A
1100A
1KHz
0.1Hz

 

Resistance (Ω) (Autorange & Manual) 

Range

Resolution

Accuracy

Open circuit

Voltage

Overload protection

400Ω

0.1Ω

±(1% + 5)

≦ 0.5 VDC

600Vrms

4KΩ

0.001KΩ

±(1% + 3)

40KΩ

0.01KΩ

400KΩ

0.1KΩ

4MΩ

0.001MΩ

40MΩ

0.01MΩ

±(1.5% + 3)

 

Audible continuity 

Range

Continuity beeper

Open Circuit Voltage

Overload  protection

≦ 40Ω

≦ 0.5V

600Vrms

 Diode test 

Range

Resolution

Accuracy

Overload protection

                   

 

0.001V

±(1%+2)

600Vrms

 Max. open circuit Voltage: 3.2V

 Max. short circuit Current: 1.0mA (typical).

 

SPECIFICATIONS:

 

  Numerical Display            :3-3/4 digit liquid crystal  display (LCD) maximum reading 3999.

 

  Range Selection              :All ranges are selected by a single range switch.

 

  Over Range Indication     :LCD will show a "OL" flashing
         in the highest position accompanied with a continuous beeping.

                                               (except for ranges of 1000A AC, and 600VDC 600VAC ).

 

  Low Battery Indication     :The  is displayed when the battery voltage drops

                                               below the operating voltage.

 

  Sampling Rate                 :20 times/sec ( Barograph ) 

                                              2 times/sec(Digital Display)

  

  Power Source                  :one 006p 9V or IEC 6F22   or NEDA 1604 Battery.

 

  Battery Life                      :100hr approx. (Alkaline)

 

  Polarity                            :Automatic polarity " – "  display for negative input.

 

  Auto power off time         :Approx. 30 minutes

 

  Operating Temperature    :0°C to 50°C(32°F to 122°F)  and Humidity  below 80%RH

 

  Storage Temperature      :-10°C to 60°C(14°F to 140°F)  and Humidity below 70%RH

 

  Dimensions                     :239(L)×66(W)×34(H)mm 

  Weight                            :Approx. 430g 

 Accessories                     :Instruction manual, Battery, Test leads, Carry Case.