New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Digital Insulation Tester
Insulation Tester (RS-232 Interface)
- With PC Software Interface
- 3-3/4 Digital LCD, 4000 Count
- Auto Range for Mega Ohm range
- 50 segments Log Scaled Analog Display
- Easy to carry testing package
- Tests insulation at rated voltage into a 1mA load
- 200mA short circuit continuity current
- Meet IEC61557
- Via RS-232 interface to talk with PC (Window Versions)
- 16,000 Record data logging capacity
- Auto discharge CAT II pollution 2 1000V CAT III pollution 2 600V
ELECTRICAL SPECIFICATIONS :
◊ OHMS & Continuity Beeper
Range |
Resolution |
Accuracy |
Max. open Circuit Voltage |
Max. Short Circuit Current |
Overload Protection |
40Ω |
0.01Ω |
1%+30 |
12.8V |
>200mA |
220Vrms |
Range |
Resolution |
Beeper Active |
Max. open Circuit Voltage |
Overload Protection |
![]() |
0.01Ω |
Resistance<4Ω |
12.8V |
220Vrms |
◊ AC Voltage (40Hz ~ 500Hz)
Range |
Resolution |
Accuracy (above 1V) |
Input Impedance |
Overload Protection |
600V |
0.1V |
1.5%+3 |
4.5MΩ |
750Vrms |
◊ Meg OHMS (Auto Range)
Range |
Resolution |
Accuracy |
Terminal Voltage |
4MΩ/40MΩ/400MΩ/ 4000MΩ/250V
|
1K |
3%+5 (<2000M) 5%+5 (>2000M) |
250V+20%~-0% |
4MΩ/40MΩ/400MΩ/ 4000MΩ/500V |
500V+20%~-0% |
||
4MΩ/40MΩ/400MΩ/ 4000MΩ/1000V |
1000V+10%~-0% |
Range |
Test Current |
Short circuit current |
|
4000MΩ/250V |
1mA |
250KΩ (load) |
≦1.5mA |
4000MΩ/500V |
500KΩ (load) |
||
4000MΩ/1000V |
1MΩ (load) |
General Specifications :
Display |
80 x 50mm Big LCD penal with 50 segments analog display Max Reading 4000 |
Over range Indication |
“OL” will be shown on the LCD penal when out of range measurement is made. |
Low Battery Indication |
The |
Sampling Rate |
2.5 times/sec Digital Display |
Power Source |
Eight 1.5Volt AA size Battery |
Operating Temperature and Humidity |
0°C to 40°C (32°F to 104°F ), below 80% RH |
Storage Temperature |
-10°C to 60°C ( 14°F to 140°F ) |
Dimension |
190(L)x140(W)x77(H)mm |
Weight |
Approx. 900g (with battery) |
Accessories |
Test leads, 8pcs battery, Carrying case, operation manual, CD software |