New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Flexible AC Current Clamp
![Flexible AC Current Clamp](/img/Product/3001.jpg)
Flexible AC Current Clamp
- AC current up to 3000A (True RMS)
- AC voltage up to 600V (True RMS)
- Frequency of ACA or ACV: 45~65Hz
- Direct reading, no DMM required
- AC current (TRMS) measurement at with 1% of scale basic accuracy
- AC voltage (TRMS) measurement at with 0.5% basic accuracy
- Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
- Max, Min and Data Hold functions
- Auto power off - 15 minutes
- Range selection: auto
- Low battery indication
Electrical Specifications: (23℃±5℃)
AC Current
(50 or 60 Hz, Auto Range, True RMS, Crest Factor < 4, Conductor is located at the
center of flexible loop. Position sensitivity is 2% of range. External field effect of
< 40A/m and 200mm from the coupling is 1% of range.
Temperature coefficient is 0.02% of reading/°C.)
Range
|
Resolution
|
Accuracy of Readings
|
0 – 300.0A
|
0.1A
|
±1% of range
|
300.0 – 999.9A
|
0.1A
|
±1% of range
|
1000 – 3000 A
|
1 A
|
±1% of range
|
AC Voltage
(50 or 60 Hz, Auto Range, True RMS, Crest Factor < 4, Input Impedance 10 MΩ,
Overload Protection AC 800V)
Range | Resolution | Accuracy of Readings |
4.0 V – 600.0 V | 0.1 V | ±0.5% ± 5dgts |
Frequency
of ACV (RMS value > 30V) or ACA (RMS value > 30A)
Range | Resolution | Accuracy |
45 – 65 | 0.1 | ± 0.2Hz |
General Specifications:
Probe Length: 3000-24 |
24 in / 610 mm |
Minimum Bending Diameter: |
35mm |
Connector Diameter: |
23mm |
Cable Diameter: |
14mm |
Cable Length from Probe to Box: |
1700mm |
Cable Length from Box to Output: |
1700mm |
Dimension (Box): |
130mm(L) x 80mm(W)x 43mm(H) 5.1”(L) x 3.1”(W) x 1.7”(H) |
Battery Type: |
two 1.5V SUM-3 |
Display: |
4+4 digits LCD |
Range Selection: |
Auto |
Overload Indication: |
OL |
Power Consumption: |
10mA(approx.) |
Low battery Indication: |
|
Auto-Power-Off: |
15 minutes after power-on |
LCD Update Time: |
2 times/sec. |
No. Of Samples per Period |
512 (voltage or current) 256 (power) |
Operating Temperature: |
-10°C to 85°C |
Operating Humidity: |
15% to 85% RH |
Altitude: |
up to 2000M |
Storage Temperature: |
-20°C to 85°C |
Storage Humidity: |
15% to 85% RH |
Weight: |
430g (battery included) |
Accessories: |
Test leads Carrying case x 1 Users manual x 1 Batteries 1.5V x 2 |