- New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo-Hygro-Barometer
- wind speed wind volume wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Flexible AC Current Clamp
Flexible Power Quality Tester
- AC current measurement up to 3000A (True RMS): basic accuracy 1% of range
- AC voltage measurement up to 600V (True RMS): basic accuracy 0.5% of range
- AC watt measurement up to 9999KW: basic accuracy 1% of range
- Power quality analysis for single and balanced 3 phase system
- Measurement of balanced 3Φ power quality and phase sequence
- Active (W, KW, HP), Reactive (VAR, KVAR) and Apparent (VA, KVA) power
- Power factor (PF), Phase angle (Φ), and Energy (WH, KWH)
- 1 to 50th order of harmonics at 2.0% basic accuracy
- Total harmonic distortion (%THD-F) and Crest factor (CF)
- Frequency of ACV or ACA: 45 ~ 65 Hz
- Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
- Work with PC via USB interface
- Programmable CT ratio from 1 to 250
- Max / Min / Data Hold functions
- Auto power off function in 30 minutes
- Data logging memory size: 8000 records
Electrical Specifications: (23℃±5℃)
AC Watt
(50 or 60 Hz, PF 0.5 to 1, CT=1, V>AC 5V, Current>AC 5A for A range)
Range
(5 to 3000A)
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
< 20V or < 30A
|
||
10.0 – 999.9 W
|
0.1W
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% of range
|
±2% of range
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% of range
|
±2% of range
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% of range
|
±2% of range
|
1000 – 9999 KW
|
1 KW
|
±1% of range
|
±2% of range
|
AC Apparent Power (VA, from 0.000VA to 9999 KVA)
Range (5 to 3000A) |
Resolution | Accuracy of Readings | |
> 20 V and > 30A | < 20V or < 30A | ||
10.0 – 999.9 VA | 0.1VA | ±1% of range | ±2% of range |
1.000 – 9.999 KVA | 0.001 KVA | ±1% of range | ±2% of range |
10.00 – 99.99 KVA | 0.01 KVA | ±1% of range | ±2% of range |
100.0 – 999.9 KVA | 0.1 KVA | ±1% of range | ±2% of range |
1000 – 9999 KVA | 1 KVA | ±1% of range | ±2% of range |
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR)
Range (5 to 3000A) |
Resolution |
Accuracy of Readings | |
> 20 V and > 30A | < 20V or < 30A | ||
10.0 – 999.9 VAR | 0.1VAR | ±1% of range | ±2% of range |
1.000 – 9.999 KVAR | 0.001 KVAR | ±1% of range | ±2% of range |
10.00 – 99.99 KVAR | 0.01 KVAR | ±1% of range | ±2% of range |
100.0 – 999.9 KVAR | 0.1 KVAR | ±1% of range | ±2% of range |
1000 – 9999 KVAR | 1 KVAR | ±1% of range | ±2% of range |
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
|
> 20V and > 30A
|
< 20V or < 30A
|
||
0.000 – 1.000
|
0.001
|
± 0.04
|
±0.1
|
AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4, CT=1)
Range
|
Resolution
|
Accuracy of Readings
|
5.0 – 300.0A
|
0.1A
|
±1% of range
|
300.0 – 999.9A
|
0.1A
|
±1% of range
|
1000 – 3000 A
|
1 A
|
±1% of range
|
AC Voltage (50/60 Hz, Auto Range, TRMS, C.F.<4, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
4.0 V – 600.0 V
|
0.1 V
|
±0.5% ± 5dgts
|
Harmonics of AC Voltage in Percentage
Range | Resolution | Accuracy |
1 – 20th | 0.1% | ±2% |
21 – 50th | 0.1% | 4% of reading ± 20dgts |
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 50th
|
0.1V
|
4% of reading ±0.5V
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
0.1%
|
4% of reading ± 20dgts
|
Harmonics of AC Current in Magnitude (True RMS<300A)
Range (5 – 300A) | Resolution | Accuracy |
1 – 20th | 0.1A | ±2% of reading ±0.4A |
21 – 50th | 0.1A | ±4% of reading ±0.4A |
Harmonics of AC Current in Magnitude (3000A>True RMS>300A)
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1A
|
±2% of reading ±40A
|
21 – 50th
|
0.1A
|
±4% of reading ±40A
|
Phase Angle (Φ, V > 20V, A > 30A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 1°
|
0° to 360°
|
0.1°
|
± 1°
|
Total Harmonic Distortion
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
0.1%
|
± 6% of reading ± 1%
|
100 – 999.9 %
|
0.1%
|
± 10% of reading ± 1%
|
Peak Value of AC Voltage (RMS value > 10V) or AC Current (RMS value > 30A)
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
39 μs
|
± 5% ± 30 digits
|
60 Hz
|
33 μs
|
± 5% ± 30 digits
|
Crest Factor (C.F.) of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range | Resolution | Accuracy of Readings |
1.00 – 99.99 | 0.01 | ± 5% ± 30 digits |
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range
|
Resolution
|
Accuracy
|
45 – 65
|
0.1
|
± 0.2Hz
|
General Specifications:
Probe Length: 3005-24
|
24 in / 610 mm
|
Minimum Bending Diameter:
|
35mm
|
Connector Diameter:
|
23mm
|
Cable Diameter:
|
14mm
|
Cable Length from Probe to Box:
|
1700mm
|
Cable Length from Box to Output:
|
1700mm
|
Dimension (Box):
|
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
|
Battery Type:
|
two 1.5V SUM-3
|
Battery life:
|
200hrs @ 2000mAH.
|
Display:
|
4+4 digits LCD
|
Range Selection:
|
Auto
|
Overload Indication:
|
OL
|
Power Consumption:
|
10mA(approx.)
|
Low battery Indication:
|
|
Auto-Power-Off:
|
30 minutes after power-on
|
LCD Update Time:
|
2 times/sec.
|
No. Of Samples per Period
|
512 (voltage or current)
256 (power)
|
Data logging memory size:
|
8000 records
|
Data logging sampling time:
|
0~600 sec
|
Data logging period:
|
8000 x sampling time (0~600 sec.)
|
Operating Temperature:
|
5°C to 50°C
|
Operating Humidity:
|
15% to 85% RH
|
Altitude:
|
up to 2000M
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
15% to 85% RH
|
Weight:
|
430g (battery included)
|
Accessories:
|
Test leads
Carrying case x 1
Users manual x 1
Batteries 1.5V x 2
Software CD x 1