New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Flexible AC Current Clamp
Graphic Power Quality Analyzer
- Power Quality Analysis for Single and Balanced Three Phase System
- Harmonic Analysis of Voltage and Current (1 to 50th order)
- True RMS measurement of V with 0.5% basic accuracy
- True RMS measurement of A with 1% of range basic accuracy
- Graphic Waveform of Voltage and Current
- Graphic Phasor Diagram
- Transient Detection and Logging of Swell, Dip, and Outage
- Fast peak function (39μs for 50 Hz, 33μs for 60Hz)
- Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power
- Power factor (PF), phase angle (Φ), and energy (WH, KWH)
- Measurement of balanced 3Φ Power Quality
- Programmable VT ratio from 1 to 3000
- Hold functions
- Auto power off function in 15 minutes
Electrical Specifications: (23℃±5℃)
AC Watt
Range
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
< 20V or < 30A
|
||
10.0 – 999.9 W
|
0.1W
|
±1% of Range ±0.3W
|
±2% of Range
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% of Range ±0.003KW
|
±2% of Range
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% of Range ±0.03KW
|
±2% of Range
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% of Range ±0.3KW
|
±2% of Range
|
1000 – 9999 KW
|
1 KW
|
±1% of Range ±3KW
|
±2% of Range
|
AC Apparent Power (VA)
Range
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
|||
10.0 – 999.9 VA
|
0.1VA
|
±1% of Range ±0.3VA
|
±2% of Range
|
1.000 – 9.999 KVA
|
0.001 KVA
|
±1% of Range ±0.003KVA
|
±2% of Range
|
10.00 – 99.99 KVA
|
0.01 KVA
|
±1% of Range ±0.03KVA
|
±2% of Range
|
100.0 – 999.9 KVA
|
0.1 KVA
|
±1% of Range ±0.3KVA
|
±2% of Range
|
1000 – 9999 KVA
|
1 KVA
|
±1% of Range ±3KVA
|
±2% of Range
|
AC Reactive Power (VAR)
Range
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
|||
10.0–999.9 VAR
|
0.1VAR
|
±1% of Range ±0.3VAR
|
±2% of Range
|
1.000–9.999 KVAR
|
0.001 KVAR
|
±1% of Range ±0.003KVAR
|
±2% of Range
|
10.00–99.99 KVAR
|
0.01 KVAR
|
±1% of Range ±0.03KVAR
|
±2% of Range
|
100.0–999.9 KVAR
|
0.1 KVAR
|
±1% of Range ±0.3KVAR
|
±2% of Range
|
1000 – 9999 KVAR
|
1 KVAR
|
±1% of Range ±3KVAR
|
±2% of Range
|
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
|
> 20V & > 30A
|
< 20V or < 30A
|
||
0.000 – 1.000
|
0.001
|
± 0.04
|
±0.1
|
AC Current
Range
|
Resolution
|
Accuracy of Readings
|
3A – 300.0A
|
0.1A
|
±1% of Range ±0.3A
|
300.0 – 3000A
|
0.1A / 1A
|
±1% of Range ±3A
|
AC Voltage (Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
4.0 V – 600.0 V
|
0.1 V
|
±0.5% ± 5dgts
|
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
0.1%
|
4% of reading ±2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% ± 0.5V
|
21 – 50th
|
0.1%
|
4% of reading ±0.5V
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
0.1%
|
±6%
|
Harmonics of AC Current in Magnitude (True RMS < 300A)
Range (0 – 300A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of range ±0.4A
|
21 – 50th
|
0.1%
|
±4% of range ±0.4A
|
Harmonics of AC Current in Magnitude (3000A >True RMS> 300A)
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of range ±40A
|
21 – 50th
|
0.1%
|
±4% of range ±40A
|
Phase Angle (Φ, V > 20V, A > 30A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 2°
|
0° to 360°
|
0.1°
|
± 2°
|
Total Harmonic Distortion
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
0.1%
|
± 7%
|
100 – 999.9 %
|
0.1%
|
± 11%
|
Peak Value of AC Voltage (RMS value > 20V) or AC Current (RMS value > 30A)
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
39 μs
|
± 5% ± 50 digits
|
60 Hz
|
33 μs
|
± 5% ± 50 digits
|
Frequency of AC Voltage (RMS value > 20V) or AC Current (RMS value > 30A)
Range |
Resolution |
Accuracy |
46 – 65 |
0.1 |
± 0.3Hz |
General Specifications:
Probe Length: 6300-24 |
24 in / 610 mm |
Minimum Bending Diameter: |
35mm |
Connector Diameter: |
23mm |
Cable Diameter: |
14mm |
Cable Length from Probe to Box: |
1700mm |
Cable Length from Box to Output: |
1700mm |
Data Logging Memory Size: |
512K bytes |
Maximum Transient Events: |
32000 |
Dimension (Box): |
130 (L) x 80 (W) x 43 (H) mm 5.1” (L) x 3.1” (W) x 1.7” (H) |
Battery Type: |
two 1.5V SUM-3 |
Display: |
128 X 64 Dot Matrix LCD with Backlight |
Range Selection: |
Auto |
Overload Indication: |
OL |
Power Consumption: |
10mA (approx) |
Auto-Power-Off: |
15 minutes after power-on |
LCD Update Time: |
2 times/sec. |
No. Of Samples per Period |
512 (voltage or current); 256 (power) |
Operating Temperature: |
-10°C to 85°C |
Operating Humidity: |
15% to 85% RH |
Altitude: |
up to 2000M |
Storage Temperature: |
-20°C to 85°C |
Storage Humidity: |
15% to 85% RH |
Weight: |
430g (battery included) |
Accessories: |
Test leads (red/black) x 1 set Users manual x 1 Batteries 1.5V x 2 Carrying Case x 1 Software CD x 1 Software users manual x 1 USB to RS232 cable x 1 |