New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
HVAC Trms Clamp Meter
AC/DC 1000A Power Clamp Meter
- Communication with PC
- 4000 Continuity Point Data Logger , 25 point manual Data Logger
- True Power / Apparent Power / Power Factor Measurement
- True RMS. V, A, W, cap, Ind, phase indicator
- 4 digits with dual Display LCD
- MIN / MAX Measurement
- Amp / Voltage Frequency Measurement
- PEAK HOLD Detector
- Dual display KW + PF , KVA + PF , V+A
- Dual display A + Hz , V + Hz
ELECTRICAL SPECIFICATIONS :
⊕ TRUE power & Apparent power measurement
Input
|
Resolution
|
Accuracy
|
Frequency
range
|
Overload protection
|
V
|
0.01
|
±(2%+5)
|
45Hz~
500Hz |
600V/1100A
|
V>130V , A<150A
|
||||
V150A
|
||||
V>130V , A>150A
|
0.1
|
±(2%+1)
|
⊕ DCA
Range |
Resolution |
Accuracy |
Overload protection |
5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
1100A |
⊕ ACA
Range |
Resolution |
Accuracy |
Frequency range |
Overload protection |
5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
45Hz~500Hz |
1100A |
※ Crest Factor :
⊕ DCV
Range |
Resolution |
Accuracy |
Input Impedance |
Overload protection |
5 ~ 600V |
0.1V |
±(0.5%rdg+5dgts) |
1MΩ |
600V |
⊕ ACV
Range |
Resolution |
Accuracy |
Input Impedance |
Frequency Range |
Overload protection |
5 ~ 600V |
0.1V |
± ( 0.5%rdg + 5dgts) |
1MΩ |
45Hz~500Hz |
600Vrms |
※Crest Factor : 3 for stated accuracy
⊕ Peak Indication:
Range |
Resolution |
Accuracy |
Overload protection |
20A~80A |
0.1A |
±(10%rdg+10dgts) |
1100A |
80A~1000A |
±(6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
⊕ Peak Indication:
Range |
Resolution |
Accuracy |
Overload protection |
20V~80V |
0.1V |
±(10%rdg+10dgts) |
600Vrms |
80V~600V |
±( 6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
⊕ Audible continuity
Range |
Continuity beeper |
Open circuit voltage |
Overload protection |
![]() |
≦ 0.050 |
≦3.2V |
600Vrms |
⊕ Resistance ( Ω )
Range |
Resolution |
Accuracy |
Open circuit voltage |
Overload protection |
10KΩ |
1Ω |
±( 1 ﹪rdg + 5dgts) |
≦ 3.2 V |
600Vrms |
⊕ Diode test
Range |
Resolution |
Overload protection |
![]() |
0.001V |
600Vrms |
⊕ Frequency ( Hz )
Range |
Resolution |
Accuracy |
Voltage sensitivity |
Overload protection |
1KHz |
0.1Hz |
±(0.5﹪rdg+5dgts) |
10V or 10A |
600V / 1100A |
5KHz |
1Hz |
⊕ Optional Accessories:
TES-3064 Connecting adaptor & PC software.
General Specifications :
Maximum Voltage between any terminal and earth ground: :600Vrms
Numerical Dual Display :4 digit liquid crystal display (LCD) maximum reading 9999.
Bargraph display :40 Segments.
Battery Life :30hr approx. (Alkaline)
Jaw Opening Diameter :Cables φ46mm.
Operating Temperature :0ºC to 50°C (32°F to 122°F)
and Humidity R.H. < 80% non-condensing.
Storage Temperature :-10°C to 60°C (14°F to 140°F)
and Humidity R.H. < 70% non-condensing.
Dimensions :260mm(L) x 93mm(W) x 45mm(H)
Weight :Approx. 450 g
Accessories :Carrying Case, Test leads,
Battery & Instruction manual