Power Analyzer

Home > Products > DC/AC Power Analyzer > 3P4W POWER ANALYZER
3P4W POWER ANALYZER
TES-3600N

3P4W POWER ANALYZER

Product Features
  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M, 3P3W3M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF,θ,Hz, &
    Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (50 sets).
  • Data Logging
  • USB Optical Interface with three phase voltage /
    current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.

ELECTRICAL SPECIFICATIONS (23±5) : 

q Voltage Measurement (V) :

 

Range

Resolution

Accuracy

Input impedance

Overload protection

Nominal power system frequency

999.9V

0.1V

±(0.3%rdg±10dgts) (>10V)

2MΩ

1000Vrms

45Hz ~ 66Hz

 

q AC Current Trms Measurement (A) Autoranging :

Range Resolution Accuracy(including current probe) Current probe output Overload protection Nominal power system frequency
999.9A 0.1A ±(0.5%rdg±15dgts)
(>10A)
0.35mV/A 1000Arms 45Hz ~ 66Hz

q Active Power measurement P (KW) :

Range

Resolution

Accuracy

999.9KW

0.1KW

±1.0%rdg±20dgts

q Apparent Power measurement S (KVA) :

Range

Resolution

Accuracy

999.9KVA

0.1KVA

±1.0%rdg±20dgts

q Reactive Power measurement Q (KVAR) :

Range

Resolution

Accuracy

999.9KVAR

0.1KVAR

±1.0%rdg±20dgts

q Power Factor measurement (COSØ) :

Range

Resolution

Calculated Accuracy

-1  ~  +1

0.001

±10dgts

q Phase angle measurement (Ø) :

Range

Resolution

Calculated Accuracy

+180°~ 0°~ -180°

0.1°

±15dgts

 q Frequency measurement (Hz) :

Range

Resolution

Accuracy

Measurement source

60HZ

0.1Hz

±0.1%rdg±2dgts

Voltage U1 > 10V

q Three Phase Sequency Detection :

Input voltage range

Normal phase indication

Reverse phase indication

Measurement source

3P > 10V

U1, U2 and U3

q Power Energy measurement (Wh, VAh, varh) :

Range

Resolution

Active power

accuracy

Timer interval

Timer Accuracy

9.999K

0.001K

Wh : ±1.0%rdg±20dgts

 

VAh : ±1.0%rdg±20dgts

 

varh : ±1.0%rdg±20dgts

1 sec

±50ppm
(25, 77)

99.99K

0.01K

999.9K

0.1K

9.999M

0.001M

30.59M

0.01M

q Harmonic measurement (use only PC on line analyzer) :

Order

Accuracy

Harmonic Source

1 ~ 63

±3%THD

U1, U2, U3 > 10V 

I1, I2, I3 > 10A

q Waveform (use only PC on line displayed).

Select Phase A, B or C.

Select the Voltage and current waveform outputs.

  

General Specifications :

Size

235(L)x116(W)x54(H)mm  (9.3"Lx4.6"Wx2.1"H)

Operating Temperature and  Humidity

0to 40 (32 to 104) R.H. < 80% non-condensing

Storage Temperature and  Humidity

-10to 60 (14to 140) R.H. < 70% non-condensing

Accessories

© Instruction manual     

© Software CD-ROM / Optical USB interface

© Deluxe carrying case        

© Battery ( “AA” 1.5V x 8pcs )

© AC adaptor (110V→12V ; 220V→12V) 

© 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters)
              
 (1000A AC,  jaw opening 42mm)

© 4pcs crocodiles test leads

   (blue, yellow, red, black, wire length 3 meters)