PRODUCT CATALOG
-
New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
HVAC Trms Clamp Meter
PROVA-6601
AC/DC 2000A Power Clamp Meter
Product Features
- 3-phase (4W, 3W) and 1-phase (2W, 3W) power measurement
- AC+DC true power: 0 ~ 1200KW (AC 600V, DC 800V, ACA/DCA 2000A)
- AC+DC voltage (True RMS): 0 ~ 600V
- AC+DC current (True RMS): 0 ~ 2000A
- AC+DC 1200KW (1-phase), AC+DC 2000KW (3-phase)
- Dual display V+Hz, A+V, W+PF, KVA+KVAR
- PF for 3-phase (4W, 3W) and 1-phase (2W)
- Frequency measurement
- Memory of 4 records
- AC/DC auto detection
- Auto range
- Jaw diameter: 55mm
- Low battery indication
Electrical Specifications: (23℃±5℃)
AC+DC True Power: ( PF 0.2 - 1.0, 3Φ3W, 3Φ4W, 1Φ2W, and 1Φ3W)
Range
|
Resolution
|
Accuracy(of reading)
|
Range
|
0 - 99.99KW
|
0.01KW
|
±2.0%±0.05KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
100 - 999.9KW
|
0.1KW
|
±2.0%±0.5KW
|
|
1000-1200KW
|
1KW
|
±2.0%±5KW
|
KW Autoranging Map: (PF 0.2 - 1.0, 3Φ3W, 3Φ4W, 1Φ2W, and 1Φ3W)
|
0V – 200V
|
200V - 600VAC, 200V - 800VDC
|
0A - 200A
|
0.00 - 40.00KW
|
0.00 - 99.99KW, 100.0 - 160.0KW
|
200A - 2000A
|
0.0 - 400.0KW
|
0.0 - 999.9KW, 1000 - 1600KW
|
AC+DC Voltage:
(True RMS, Crest Factor<4, Autorange, Overload Protection 800VAC for all ranges.)
Range
|
Resolution
|
Accuracy (of reading)
|
Input Impedance
|
|
DC, 50/60 Hz
|
40 - 400Hz
|
|||
0-200V
|
0.1V
|
±1.5%±5dgts
|
±2.0%±5dgts
|
10MΩ
|
200-500V
|
0.1V
|
±1.5%±5dgts
|
±2.0%±5dgts
|
10MΩ
|
500-600V
|
1V
|
±1.5%±5dgts
|
±2.0%±5dgts
|
10MΩ
|
AC+DC Current: (True RMS, Crest Factor < 4)
Range
|
Resolution
|
Accuracy (of reading)
|
Overload Protection
|
|
DC, 50/60 Hz
|
40 - 400Hz
|
|||
0-200A
|
0.1A
|
±1.5%±5dgts
|
±2.0%±5dgts
|
AC 3000A
|
200-500A
|
0.1A
|
±2.0%±5dgts
|
±2.5%±5dgts
|
AC 3000A
|
500-2000A
|
1A
|
±2.5%±5dgts
|
±3.0%±5dgts
|
AC 3000A
|
AC+DC KVAR: (Reactive Power, 3∅3W, Sine Wave)
Range
|
Resolution
|
Accuracy (of reading)
|
Range
|
0 - 99.99KW
|
0.01KW
|
±2.0%±0.5KW
|
AC 600V, DC 800V, ACA/DCA 2000A
|
100 - 999.9KW
|
0.1KW
|
±2.0%±0.5KW
|
|
1000-1200KW
|
1KW
|
±2.0%±5KW
|
Frequency: (if < 10 Hz, Hz = 0)
Range | Accuracy | Sensitivity |
50/60 Hz | ±2digits | V: > 1V, A: > 5A |
10 – 1000 Hz | 1.5% ± 2 digits | V: > 1V, A: > 5A |
General Specifications:
Conductor Size:
|
Cable 55mm. (approx.)
Bus Bar 65mm(D) x 24mm(W)
|
Battery Type:
|
9V
|
Display:
|
2 X 4 Digits Dual Display LCD
|
Range Selection:
|
Auto
|
Overload Indication:
|
OL
|
Power Consumption:
|
25mA (approx.)
|
Low battery Indication:
|
![]() |
Sampling Time:
|
0.5 sec. (V and A)
1.6 sec. (W)
|
Operating Temperature:
|
4°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Altitude:
|
up to 2000M
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
271mm (L) x 112mm (W) x 46mm (H)
10.7" (L) x 4.4" (W) x 1.8" (H)
|
Weight:
|
647g / 22.8 oz (battery included)
|
Accessories:
|
Carrying bag x 1
Users manual x 1
Battery 9V x 1, installed
|