- New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo-Hygro-Barometer
- wind speed wind volume wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Power Analyzer
Power and Harmonics Analyzer
- Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
- True RMS value (V123 and I123)
- Active Power (W, KW, MW, GW)
- Apparent and Reactive Power (KVA, KVAR)
- Power Factor (PF), Phase Angle (Φ)
- Energy (WH, KWH, KVARH, PFH)
- AC Current (0.04A to 6000A) and Voltage measurement: True RMS, Auto Range.
- Capable of analyzing IT standby power consumption to the maximum demand of a factory
- Display of 35 Parameters in One Screen (3P4W)
- Programmable CT (1 to 600) and PT (1 to 3000) Ratios
- Display of Overlapped Voltage and Current Waveform
- Average Demand (AD in W, KW, MW)
- Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
- Harmonic Analysis to the 99th Order
- Display of 50 Harmonics in one Screen with Waveform
- Display of Waveform with Peak Values (1024 Samples / Period)
- Analysis of Total Harmonic Distortion (THD-F)
- Graphic Phasor Diagram with 3 Phase System Parameters
- Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
- DIP, SWELL, and OUTAGE are included in transient events.
- 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
- 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
- Calculated Unbalanced Current through Neutral Line (In)
- 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
- Output of Waveform, Power Parameters and Harmonics at Command
- Large Dot Matrix LCD Display with Backlight
- Software to work with PC via Optical Isolated RS-232C to USB Interface
- Built-in timer and calendar for data logging
- Conductor Size:
■ Model 6801 (100A)
30mm(approx),210mm(L) x 62mm(W) x 36mm(H),200g(Weight)
■ Model 6802 (1000A)
55mm(approx),64*24mm(bus bar)
244mm (L) x 97mm(W) x 46mm(H),600g(Weight)
■ Model 3007 (3000A)
24in/610mm(Probe Length)
130mm(L) x 80mm(W) x 43mm(H),410g(Weight)
■ Model 3009 (1200A)
18in/460mm(Probe Length)
130mm(L) x 80mm(W) x 43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
PROVA-6830A + 6801 (100A)
Electrical Specifications: (23℃±5℃)
AC Watt
Range (0 to 100A)
|
Resolution
|
Accuracy of Readings
|
5.0 – 999.9 W
|
0.1W
|
±1% ± 0.8W
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% ± 8W
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% ± 80W
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% ± 0.8KW
|
1000 – 9999 KW
|
1 KW
|
±1% ± 8KW
|
Range of CT (Current Transformer) Ratio: 1 to 600
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 200A)
Range
|
Resolution
|
Accuracy of Readings
|
0.04 – 1 A
|
0.1mA / 1mA
|
±0.5% ± 0.05A
|
0.4 – 10 A
|
0.001A / 0.01A
|
±0.5% ± 0.05A
|
4 – 100 A
|
0.01A / 0.1A
|
±1.0% ± 0.5A
|
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
|
50 – 99th
|
±6% of reading ± 0.5V
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 10th
|
0.1%
|
±0.2% of reading ± 1%
|
11 – 20th
|
±2% of reading ± 1%
|
|
21 – 50th (A range)
|
±5% of reading ± 1%
|
|
21 – 50th (mA range)
|
±10% of reading ± 1%
|
|
51 - 99th
|
±35% of reading ± 1%
|
Harmonics of AC Current in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 10th
|
0.1mA / 0.1A
|
±0.2% of reading ±7dgts
|
11 – 20th
|
±2% of reading ±7dgts
|
|
21 – 50th (A range)
|
±5% of reading ±7dgts
|
|
21 – 50th (mA range)
|
±10% of reading ±7dgts
|
|
51 - 99th
|
±35% of reading ±7dgts
|
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
0.00 – 1.00
|
0.01
|
± 0.04
|
Phase Angle (Φ)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 1°
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 10% of the range), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V)
or ACA (peak value > 10% of the range), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
Frequency in AUTO mode
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1Hz
|
± 0.1Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20.0 %
|
0.1%
|
± 1%
|
20.0 – 100%
|
±3% of reading ± 5%
|
|
100 – 999.9%
|
±10% of reading ±10%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter
Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 6801) x 3
Test leads (3 meter long) x 4
Alligator clips x 4
Carrying bag x 1
Users manual x 1
Batteries 1.5V x 8
AC power adapter x 1
Software CD x 1 Software users manual x 1 USB to RS232 cable x 1 |
PROVA 6801 Current Probes
Conductor Size:
|
30mm (approx.)
|
Cable Length:
|
3000mm
|
Range Selection:
|
Manual (1A, 10A, 100A)
|
Battery:
|
powered by power analyzer
|
Dimension:
|
210mm (L) x 62mm (W) x 36mm (H)
8.3" (L) x 2.5" (W) x 1.4" (H)
|
Weight:
|
200g
|
PROVA-6830A + 6802 (1000A)
Electrical Specifications: (23℃±5℃)
AC Watt
Range (0 to 1000A)
|
Resolution
|
Accuracy of Readings
|
5.0 – 999.9 W
|
0.1W
|
±1% ± 0.8W
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% ± 8W
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% ± 80W
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% ± 0.8KW
|
1000 – 9999 KW
|
1 KW
|
±1% ± 8KW
|
0.000 – 9.999MW
|
0.001MW
|
±1% ± 80KW
|
Range of CT (Current Transformer) Ratio: 1 to 600
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH):
WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 2000A)
Range
|
Resolution
|
Accuracy of Readings
|
10.00A
|
0.001A/0.01A
|
–
|
5A - 100.0A
|
0.01A/0.1A
|
±0.5% ± 0.5A
|
50A – 1000.0 A
|
0.1A/1 A
|
±0.5% ± 5A
|
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
|
50 – 99th
|
±6% of reading ± 0.5V
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1 %
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Current in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1A
|
±2% of reading ±0.4A
|
21 – 49th
|
±4% of reading ±0.4A
|
|
50 – 99th
|
±6% of reading ±0.4A
|
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
0.00 – 1.00
|
0.01
|
± 0.04
|
Phase Angle (Φ)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 1°
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 20A), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 20A), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
Frequency in AUTO mode
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1Hz
|
± 0.1Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
± 6% of reading ± 1%
|
|
100 – 999.9 %
|
± 10% of reading ± 1%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter
Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 6802) x 3
Test leads (3 meter long) x 4
Alligator clips x 4
Carrying bag x 1
Users manual x 1
Batteries 1.5V x 8
AC power adapter x 1
Software CD x 1 Software users manual x 1 USB to RS232 cable x 1 |
PROVA 6802 Current Probes
Conductor Size:
|
55mm (approx.), 64 x 24mm (bus bar)
|
Cable Length:
|
3000mm
|
Range Selection:
|
Manual (10A, 100A, 1000A)
|
Battery:
|
powered by power analyzer
|
Dimension:
|
244mm (L) x 97mm (W) x 46mm (H)
9.6" (L) x 3.8" (W) x 1.8" (H)
|
Weight:
|
600g
|
PROVA-6830A + 3007 (3000A)
Electrical Specifications: (23℃±5℃)
AC Watt
Range
(0 to 3000A)
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
< 20V or < 30A
|
||
10.0 – 999.9 W
|
0.1W
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KW
|
0.001 KW
|
||
10.00 – 99.99 KW
|
0.01 KW
|
||
100.0 – 999.9 KW
|
0.1 KW
|
||
1000 – 9999 KW
|
1 KW
|
Range of CT (Current Transformer) Ratio: 1 to 600
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 3000A)
Range
|
Resolution
|
Accuracy of Readings
|
10.0 – 300.0A
|
0.01A / 0.1A
|
±1% of range
|
300.0 – 3000A
|
0.1A / 1A
|
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
|
50 – 99th
|
±6% of reading ± 0.5V
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 30A), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 30A), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
±6%
|
|
51 – 99th
|
±10%
|
Harmonics of AC Current in Magnitude
(1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 300A)
Range (0 – 300A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 4A
|
21 – 50th
|
±4% of reading ± 4A
|
|
51 – 99th
|
±6% of reading ± 4A
|
(1 to 99th order, min. current at the 50 or 60 Hz, 3000A > True RMS > 300A)
Range (300–3000A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 40A
|
21 – 50th
|
±4% of reading ± 40A
|
|
51 – 99th
|
±6% of reading ± 40A
|
Power Factor (PF)
Range | Resolution | Accuracy | |
> 20V and > 30A | < 20V or < 30A | ||
0.000 – 1.000 | 0.001 | ± 0.04 | ±0.1 |
Phase Angle (Φ, V > 20V, A > 30A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 2°
|
0° to 360°
|
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1 Hz
|
± 0.2Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
± 6% of reading ± 5%
|
|
100 – 999.9 %
|
± 10% of reading ± 10%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 3007) x 3
Test leads (3 meter long) x 4
Alligator clips x 4, Carrying bag x 1
Users manual x 1, Batteries 1.5V x 8
AC power adapter x 1, Software CD x 1
Software users manual x 1 USB to RS232 cable x 1 |
AFLEX 3007 Flexible Current Probes
Probe Length: ( 3007-24)
|
24 in / 610 mm
|
Minimum Bending Diameter:
|
35mm
|
Connector Diameter:
|
23mm
|
Cable Diameter:
|
14mm
|
Cable Length from Probe to Box:
|
1700mm
|
Cable Length from Box to Output:
|
1700mm
|
Range Selection:
|
Manual (300A, 3000A)
|
Battery:
|
powered by power analyzer
|
Dimension (Box):
|
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
|
Weight:
|
410g
|
PROVA-6830A + 3009 (1200A)
Electrical Specifications: (23℃±5℃)
AC Watt
Range
(0 to 1200A)
|
Resolution
|
Accuracy of Readings
|
|
> 20 V and > 30A
|
< 20V or < 30A
|
||
10.0 – 999.9 W
|
0.1W
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KW
|
0.001 KW
|
||
10.00 – 99.99 KW
|
0.01 KW
|
||
100.0 – 999.9 KW
|
0.1 KW
|
||
1000 – 9999 KW
|
1 KW
|
Range of CT (Current Transformer) Ratio: 1 to 600
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 1200A)
Range
|
Resolution
|
Accuracy of Readings
|
6.0 – 120.0A
|
0.01A / 0.1A
|
±1% of range
|
120.0 – 1200A
|
0.1A / 1A
|
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
|
50 – 99th
|
±6% of reading ± 0.5V
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 30A), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 30A), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
±6%
|
|
51 – 99th
|
±10%
|
Harmonics of AC Current in Magnitude
(1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 120A)
Range (0 – 120A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 4A
|
21 – 50th
|
±4% of reading ± 4A
|
|
51 – 99th
|
±6% of reading ± 4A
|
(1 to 99th order, min. current at the 50 or 60 Hz, 1200A > True RMS > 120A)
Range (120–1200A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 40A
|
21 – 50th
|
±4% of reading ± 40A
|
|
51 – 99th
|
±6% of reading ± 40A
|
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
|
> 20V and > 30A
|
< 20V or < 30A
|
||
0.000 – 1.000
|
0.001
|
± 0.04
|
±0.1
|
Phase Angle (Φ, V > 20V, A > 30A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 2°
|
0° to 360°
|
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1 Hz
|
± 0.2Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
± 6% of reading ± 5%
|
|
100 – 999.9 %
|
± 10% of reading ± 10%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 3009) x 3
Test leads (3 meter long) x 4
Alligator clips x 4, Carrying bag x 1
Users manual x 1, Batteries 1.5V x 8
AC power adapter x 1, Software CD x 1
Software users manual x 1 USB to RS232 cable x 1 |
AFLEX 3009 Flexible Current Probes
Probe Length: ( 3009-18)
|
18 in / 460 mm
|
Minimum Bending Diameter:
|
35mm
|
Connector Diameter:
|
23mm
|
Cable Diameter:
|
14mm
|
Cable Length from Probe to Box:
|
1700mm
|
Cable Length from Box to Output:
|
1700mm
|
Range Selection:
|
Manual (120A, 1200A)
|
Battery:
|
powered by power analyzer
|
Dimension (Box):
|
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
|
Weight:
|
390g
|
PROVA-6830A + 3006 (6000A)
Electrical Specifications: (23℃±5℃)
AC Watt
Range(0 to 6000A) | Resolution | Accuracy of Readings | |
> 20 V and > 60A | < 20V or < 60A | ||
10.0 – 999.9 W | 0.2W | ±1% of range | ±2% of range |
1.000 – 9.999 KW | 0.002 KW | ||
10.00 – 99.99 KW | 0.02 KW | ||
100.0 – 999.9 KW | 0.2 KW | ||
1000 – 9999 KW | 2 KW |
Range of VT (Voltage Transformer) Ratio: 1 to 3000
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 6000A)
Range | Resolution | Accuracy of Readings |
20.0 – 600.0A | 0.2A | ±1% of range |
600.0 – 6000A | 0.2A / 2A |
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range | Resolution | Accuracy |
1 – 20th | 0.1% | ±2% |
21 – 49th | ±4% of reading ± 2.0% | |
50 – 99th | ±6% of reading ± 2.0% |
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
|
50 – 99th
|
±6% of reading ± 0.5V
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 60A), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (RMS value > 60A), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 60 digits
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
±6%
|
|
51 – 99th
|
±10%
|
Harmonics of AC Current in Magnitude
(1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 600A)
Range (0 – 600A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 8A
|
21 – 50th
|
±4% of reading ± 8A
|
|
51 – 99th
|
±6% of reading ± 8A
|
(1 to 99th order, min. current at the 50 or 60 Hz, 6000A > True RMS > 600A)
Range (600–6000A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 80A
|
21 – 50th
|
±4% of reading ± 80A
|
|
51 – 99th
|
±6% of reading ± 80A
|
Power Factor (PF)
Range | Resolution | Accuracy | |
> 20V and > 60A | < 20V or < 60A | ||
0.000 – 1.000 | 0.001 | ± 0.04 | ±0.1 |
Phase Angle (Φ, V > 20V, A > 60A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 2°
|
0° to 360°
|
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 60A)
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1 Hz
|
± 0.2Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
± 6% of reading ± 5%
|
|
100 – 999.9 %
|
± 10% of reading ± 10%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 3006) x 3
Test leads (3 meter long) x 4
Alligator clips x 4, Carrying bag x 1
Users manual x 1, Batteries 1.5V x 8
AC power adapter x 1, Software CD x 1
Software users manual x 1 USB to RS232 cable x 1 |
AFLEX 3006 Flexible Current Probes
Probe Length: ( 3006-36 )
|
36 in / 920 mm
|
Minimum Bending Diameter:
|
35mm
|
Connector Diameter:
|
23mm
|
Cable Diameter:
|
14mm
|
Cable Length from Probe to Box:
|
1700mm
|
Cable Length from Box to Output:
|
1700mm
|
Range Selection:
|
Manual (600A, 6000A)
|
Battery:
|
powered by power analyzer
|
Dimension (Box):
|
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
|
Weight:
|
430g
|