New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Digital Earth Tester
Digital Earth Tester
- Capable of measuring earth voltage.
- Data hold function.
- Auto power off function:
The timer operates automatically about 10 minutes when the “ Test Button Switch ”are pressed to keep the tester power on. - 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
- In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
- Automatic warning when resistance of auxiliary earth spike is in excess of tolerance.
- Designed to meet EN 61010-1/ / EN 61557 safety standard.
- Zero ohm adjustment
Measuring Range and Accuracy ( at 23℃ and 45-75%RH )
Function |
Measuring range |
Accuracy |
Overload Protection |
Earth Voltage |
0 ~ 199.9V (50Hz, 60Hz)
|
±(1%rdg + 4dgts)
|
300Vrms / 1 minute |
Earth Resistance |
0 ~19.99Ω |
±(2%rdg + 0.1Ω) |
200Vrms / 10 seconds
|
0 ~ 199.9Ω |
±(2%rdg+3dgts) |
||
0 ~ 1999Ω |
Current Consumption ( typical Value with battery voltage of 9V )
Range |
ON |
20Ω/ 200Ω/2000ΩΩ |
42mA |
Earth V |
22mA |
General Specification:
q Safety Standard : EN 61010-1 overvoltage category Ⅲ,EN 61557.
q Display : 3 1/2 digit liquid crystal display with a maximum reading of 1999.
q Insulation Resistance : More than 5MΩ between the circuit and the housing case when measured with 300VDC.
q Withstand Voltage : 3700CV AC for 1 minute between the circuit and the housing case.
q Timer (Auto power off) : about 10 minutes.
q Dimensions : 165(L) ×100(W) ×57(H)mm
q Weight : Approx. 500g (with battery).
q Power Source : DC 9V (6´1.5V size “AA” battery or equivalent).
q Over range Indication : “ 1- - - - ” will be shown on the LCD panel when out of range measurement is made.
q Operating Temperature and Humidity : 0℃ to 40℃ (32℉ to 104℉) , below 80% RH.
q Storage Temperature : -10℃to 60℃ (14℉ to 140℉)
q Accessories : Test leads 1 set, Auxiliary earth spikes 2 pcs, Battery 6 pcs, Carrying case, Manual.