PRODUCT CATALOG
-
New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Digital Earth Tester
PROVA-5601
Clamp-on Ground Resistance Tester
Product Features
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- Ground Resistance Measurement: 0.025 – 1500Ω
- Leakage Current: 0.3mA – 30A, True RMS
- Jaw Diameter: 23mm
- Programmable High and Low Alarm
- Data logging capacity: 116 records
- Programmable Data Logging: data logging interval 1 to 255 sec.
- Auto-power-off function
Grounding Application: - Telecommunication
- Electrical Power Plant
- Factory and Facility
- Cable TV System
- Cellular Phone System
- Gas Station & Tank
Electrical Specifications: (23℃±5℃)
Ground Resistance (Auto range):
Range
|
Resolution
|
Accuracy of Reading1
|
0.025 - 0.250Ω
|
0.002Ω
|
± 1.5% ± 0.05Ω
|
0.251 - 1.000Ω
|
0.02Ω
|
± 1.5% ± 0.05Ω
|
1.001 – 10.00Ω
|
0.02Ω
|
± 1.5% ± 0.1Ω
|
10.01 - 50.00Ω
|
0.04Ω
|
±2.0% ± 0.3Ω
|
50.01 – 100.0Ω
|
0.04Ω
|
±2.0% ± 0.5Ω
|
100.1 - 200.0Ω
|
0.4Ω
|
± 3.0% ± 1.0Ω
|
200.1 - 400.0Ω
|
2Ω
|
± 5.0% ± 5Ω
|
400.1 - 600.0Ω
|
5Ω
|
± 10% ± 10Ω
|
600.1 – 1500Ω
|
20Ω
|
± 20%
|
1 Loop resistance noninductive, external field < 50 A/m,
external electrical field < 1 V/m, conductor centered.
2 Resistance Measurement Frequency: 3.333KHz
High and Low Alarm
|
Range
|
Resolution
|
High Alarm
|
0 - 1510Ω
|
1Ω
|
Lo Alarm
|
0 - 1510Ω
|
1Ω
|
Ground/ Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.0)
Range
|
Resolution
|
Accuracy of Reading
|
0.300 - 1.000 mA
|
0.001 mA
|
± 2.0% ± 0.05 mA
|
1.00 - 10.00 mA
|
0.01 mA
|
± 2.0% ± 0.03 mA
|
10.0 - 100.0 mA
|
0.1 mA
|
± 2.0% ± 0.3 mA
|
100 – 1000 mA
|
1 mA
|
± 2.0% ± 3 mA
|
Ground Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.0)
Range
|
Resolution
|
Accuracy of Reading
|
0.200 – 4.000 A
|
0.001 A
|
± 2.0% ± 0.03 A
|
4.00 – 30.00 A
|
0.01 A
|
± 3.0% ± 0.03 A
|
Accuracy of Resistance Calibration Plate: ±1%
Data Logging Capacity:116 records
Data Logging Interval: 1 to 255 seconds
General Specifications:
Conductor Size:
|
23 mm (0.9”) approx.
|
Jaw Opening:
|
27 mm (1.06”) approx.
|
Battery Type:
|
9V IEC 6 LR61 (Alkaline)
|
Battery Life:
|
3000 measurements
|
Display:
|
4 digits 9999 counts LCD
|
Range Selection:
|
Auto
|
Auto-Power-Off:
|
About 4~6 minutes
|
Overload Protection:
|
100A (continuous); 200A (5 sec.)
|
Overload Indication:
|
OL
|
Power Consumption:
|
40mA
|
Low Battery Indication:
|
![]() |
Sampling Time:
|
20 times / sec.
|
LCD update:
|
2 times / sec.
|
Operating Temperature:
|
0°C to 50°C (14°F to 122°F)
|
Operating Humidity:
|
less than 85% relative
|
Altitude:
|
up to 2000M
|
Storage Temperature:
|
-20°C to 60°C (-4°F to 122°F)
|
Storage Humidity:
|
less than 75% relative
|
Temperature Coefficient:
|
0.1% x (Specified Spec.) / °C
(<18°C or >28°C)
|
Dimension:
|
257mm (L) x 100mm(W) x 47mm(H)
10.1" (L) x 3.9"(W) x 1.9"(H)
|
Weight:
|
640g / 1.4 lbs
|
Accessories:
|
Resistance Calibration Plate x 1
9V Battery (Installed) x 1
Users Manual x 1
Carrying Case x 1
|
Grounding application:
■ Telecommunication
■ Telecommunication
■ Electrical Power Plant
■ Factory and Facility
■ Cable TV System
■ Cable TV System
■ Cellular Phone System
■ Gas Station & Tank
■ Gas Station & Tank