New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Thermometer
K.J.T.E.R.S.N. Thermometer
- Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type.
- Dual input function T1/T2 temperature display.
- Warning beeper with HI/LO setting.
- MAX/MIN with TIME, MAX–MIN AVG, HOLD function.
- ℃ / ℉ / K User-Selective.
- Backlight LCD display.
Measuring Range |
K - Type : -150.0°C to +1370.0°C (-200.0°F to +1999.9°F) J - Type : -150.0°C to +1090.0°C (-200.0°F to +1994.0°F) T - Type : -150.0°C to +400.0°C (-200.0°F to +752.0°F) E - Type : -150.0°Cto +870.0°C (-200.0°F to +1598.0°F) R - Type : 2.0°C to +1767.0°C (+35°F to +1999.9°F) S - Type : 2.0°C to +1767.0°C (+35°F to +1999.9°F) N - Type : -150.0°C to +1300.0°C (-200.0°F to +1999.9°F) |
|
Display Resolution |
J-, K-, T-, E-, and N-type : 0.1°C/°F/K R- and S-type : 1.0°C/°F/K (0.1°C/°F/K only for reference) |
|
Measurement Accuracy (According to ITS-90) |
K, J, E, T, and N-Type : ± [0.05% of reading +0.5°C (0.9°F)] [below –100°C (-148°F) : add 0.15 % of reading for K-, J-, E-, R-and S-Type : ± [0.05% of reading + 2°C (4°F)] |
|
Temperature Coefficient |
0.01% of reading + 0.03°C per °C (0.06°F per °F) outside the [LCD ranging : below –100°C (-148°F) : add 0.04% of reading for K-, J-, E, and N- Type; and 0.08% of reading for T- Type] |
|
Maximum Differential Common Mode Voltage |
1V (Maximum voltage difference between T1 and T2) |
|
Input Protection |
20V maximum input voltage on any |
|
Sampling Rate |
One time per 1.5 seconds. |
|
Operating/Storage Conditions |
0°C~ 50°C < 80% RH , -10°C ~ 60°C < 70%RH |
|
Power Source |
6 pcs size AAA Battery |
|
Battery Life |
Approx. 200hours. (not including backlight and beeper) |
|
Size |
150(L) ×72(W) ×35(H)mm |
|
Weight |
Approx. 235g |
|
Accessories |
Instruction manual, Battery |