PRODUCT CATALOG
- New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo-Hygro-Barometer
- wind speed wind volume wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Thermo-Hygro-Barometer
TES-1160A / TES-1161
Thermo / Hygro / Barometer
Product Features
- Triple LCD displays Barometric pressure, Temperature, and Relative humidity.
- Dew point and Wet bulb temperature reading.
- Absolute humidity, Mixing ratio and Enthalpy reading.
- Water vapor pressure and Water saturation pressure reading.
- Pressure trend and tendency (P3h) reading.
- Heat Index and Humidex reading.
- MAX/MIN with Time Stamp.
- Comparator function.
- Alarm output function.
- Auto power off function.
- Data Hold function.
- LCD backlight control function.
- Manual data memory and read function.
- Auto data logger function. (1161)
- USB Interface. (1161)
Measurement range
|
Humidity : 0% to 100%RH
Temperature : -40℃ to + 100℃ (-40℉ to +212℉)
Atmospheric pressure : 300 to 1200hPa
|
Resolution
|
0.1% RH, 0.1℃, 0.1℉, 0.1hPa
|
Accuracy
|
Temperature : ±0.4℃(at +5℃ to +60℃)
±0.8℃(at -20℃ to 5℃ and +60℃ to +80℃)
±1.2℃(at -40℃ to -20℃ and +80℃ to +100℃)
±0.8℉(at +41℉to +140℉)
±1.6℉(at -4℉ to 41℉ and +140℉ to +176℉)
±2.4℉(at -40℉ to -4℉ and +176℉ to +212℉)
Humidity :±3%RH (at 25℃, 20 to 80% RH)
±4%RH (at 25℃, 10 to 20% RH and 80 to 90% RH).
±5%RH (at 25℃, 0 to 10% RH and 90 to 100% RH).
Atmospheric pressure :±2hPa at 25℃, ±4hPa at –20 to 85℃
|
Response time (at 1m/s air flow)
|
Humidity : t63% < 10s (from 33 to 75% RH)
Temperature : t63% < 10s (from 15℃ to 45℃)
|
Display refresh rate
|
1s in FAST mode, 1s to 5s in dynamic mode
|
Data memory capacity
|
99 sets. (Direct reading from LCD display)
|
Data logger capacity
|
microSD CARD (Maximum capacity 32GB can be used), Maximum 99 blocks. (1161)
|
Alarm output
|
Open-collect output. Input impedance: 490Ω
Maximum applied Voltage: 24V DC
Maximum drive current: 50mA DC
|
Operating temperature and humidity
|
0℃to 60℃, below 95% RH
|
Storage temperature and humidity
|
-10℃ to 60℃, below 70% RH
|
Power supply
|
006P 9V or IEC6F22, NEDA 1604 battery
|
Battery life
|
Approx. 300 hours (1160A)
Approx. 1 month (1161) |
Dimensions
|
249×64×26mm (9.8”×2.52”×1.02”)
|
Weight
|
Approx. 178g (6.3oz)
|
Accessories
|
Instruction manual, Battery, Carrying case,
CD software (1161), Micro-USB cable (1161).
|
Optional accessory
|
AC adaptor DC9V (1161)
|