PRODUCT CATALOG
-
New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Vibration Meter
TES-3100
VIBRATION METER
Product Features
- Measures acceleration, Velocity and displacement
- RMS, EQ PEAK and EQ P-P measurement
- Wide range of vibration measurement by using different sensitivity of accelerometers
- Backlight LCD display
- Maximum/Minimum record function
- Earphone output for detecting noise in machine components
- Manual memory stores up to 99 data
ISO 2372 Equipment vibration standard
|
||||
Equipment category
|
Good
|
Acceptable
|
Still permissible
|
Dangerous
|
15KW the following small machinery and equipment
|
0 ~ 0.71 mm/s
|
0.72 ~ 1.80 mm/s
|
1.81 ~ 4.5 mm/s
|
> 4.5 mm/s
|
15KW-75KW medium-sized machinery and quipment
|
0 ~ 1.12 mm/s
|
1.13 ~ 2.80 mm/s
|
2.81 ~ 7.1 mm/s
|
> 7.1 mm/s
|
Large machinery and equipment
|
0 ~ 1.80 mm/s
|
1.81 ~ 4.50 mm/s
|
4.51 ~ 11.2 mm/s
|
> 11.2 mm/s
|
Large / large mechanical equipment
|
0 ~ 2.80 mm/s
|
2.81 ~ 7.10 mm/s
|
7.11 ~ 18.0 mm/s
|
> 18 mm/s
|
SPECIFICATIONS
Piezoelectric Accelerometer (PA-01)
|
|
Sensitivity
|
5mV/(m/s²)(±10%)
|
Acceleration range
|
200m/s²
|
Amplitude nonlinearity
|
±1%
|
Frequency response
|
5Hz to 10kHz (±10%), 10kHz to 15kHz (±3dB)
|
Resonance frequency
|
27kHz
|
Transverse sensitivity
|
≦5%
|
Dimensions/Weight
|
46(H) x 19(D) mm / 46g
|
Measurement range (PA-01)
|
|
ACC (Acceleration)
|
0.02 to 200m/s² EQ PEAK 1Hz to 5kHz
|
VEL (Velocity)
|
0.3 to 1000mm/s RMS 3Hz to 1kHz
0.1 to 1000mm/s RMS 10Hz to 1kHz
|
DISP (Displacement)
|
0.02 to 100mm EQ PEAK 3Hz to 500Hz
0.001 to 100mm EQ PEAK 10Hz to 500Hz
|
Frequency range
|
|
ACC (Acceleration)
|
3Hz to 1kHz, 3Hz to 5kHz, 1Hz to 100Hz, 3Hz to 20kHz
|
VEL (Velocity)
|
10Hz to 1kHz, 3Hz to 1kHz
|
DISP (Displacement)
|
1Hz to 500Hz, 3Hz to 500Hz
|
Measurement full-scale range
|
|
For accelerometer PA-01 and accelerometers with sensitivity
|
1.0 to 9.9mV/(m/s²)
|
ACC (Acceleration)
|
1, 10, 100, 1000m/s²
|
VEL (Velocity)
|
10, 100, 1000mm/s
|
DISP (Displacement)
|
0.1, 1, 10, 100mm
|
Indication characteristics
|
|
Acceleration
|
RMS, EQ PEAK
|
Velocity
|
RMS, EQ PEAK
|
Displacement
|
RMS, EQ PEAK, EQ p-p
|
Gain calibration (Accelerometer sensitivity selection establishes suitable gain)
|
|
Setting range
|
0.10 to 0.99, 1.0 to 9.9, 10 to 99mV (m/s²)
|
Ambient conditions for operation
|
|
Accelerometer
|
-20 to +70°C, max. 90%RH
|
Main unit
|
-10 to +50°C, max. 90%RH
|
Manual memory
|
Maximum 99 data can be stored manually
|
Power requirements
|
4 IEC R6 (size AA) batteries, AC adapter 6V (option)
|
Battery life (continuous use)
|
8 hours (approx.)
|
Dimensions / Weight
|
158(L) × 78(W) × 40(H)mm / 286g
|
Supplied accessories
|
Instruction manual, Battery
|