New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
Vibration Meter
VIBRATION METER
- Measures acceleration, Velocity and displacement
- RMS, EQ PEAK and EQ P-P measurement
- Wide range of vibration measurement by using different sensitivity of accelerometers
- PA-01 & PA-02 Accelerometer can be change use
- Backlight LCD display
- Auto memory micro SD card 4GB, USB interface to PC
- Maximum/Minimum record function
- Excellent accelerometer for harsh environments
- Earphone output for detecting noise in machine components
- Manual memory stores up to 99 data
ISO 2372 Equipment vibration standard
|
||||
Equipment category
|
Good
|
Acceptable
|
Still permissible
|
Dangerous
|
15KW the following small machinery and equipment
|
0 ~ 0.71 mm/s
|
0.72 ~ 1.80 mm/s
|
1.81 ~ 4.5 mm/s
|
> 4.5 mm/s
|
15KW-75KW medium-sized machinery and quipment
|
0 ~ 1.12 mm/s
|
1.13 ~ 2.80 mm/s
|
2.81 ~ 7.1 mm/s
|
> 7.1 mm/s
|
Large machinery and equipment
|
0 ~ 1.80 mm/s
|
1.81 ~ 4.50 mm/s
|
4.51 ~ 11.2 mm/s
|
> 11.2 mm/s
|
Large / large mechanical equipment
|
0 ~ 2.80 mm/s
|
2.81 ~ 7.10 mm/s
|
7.11 ~ 18.0 mm/s
|
> 18 mm/s
|
SPECIFICATIONS:
Piezoelectric Accelerometer (PA-01) |
|
Sensitivity |
5mV/(m/s²)(±10%) |
Acceleration range |
200m/s² |
Amplitude nonlinearity |
±1% |
Frequency response |
5Hz to 10kHz (±10%), 10kHz to 15kHz (±3dB) |
Resonance frequency |
27kHz |
Transverse sensitivity |
≦5% |
Dimensions/Weight |
46(H) x 19(D) mm / 46g |
Piezoelectric Accelerometer (PA-02) |
|
Sensitivity |
10mV/(m/s²)(±10%) |
Acceleration range |
100m/s² |
Amplitude nonlinearity |
±1% |
Frequency response |
5Hz to 3kHz (±10%), 3kHz to 5kHz (±3dB) |
Resonance frequency |
20 kHz |
Transverse sensitivity |
≦5% |
Dimensions/Weight |
52(H) x 22(D) mm / 72 g |
Measurement range (using PA-01 or PA-02) |
|
ACC (Acceleration) |
0.02 to 200m/s² EQ PEAK 1Hz to 5kHz |
VEL (Velocity) |
0.3 to 1000mm/s RMS 3Hz to 1kHz 0.1 to 1000mm/s RMS 10Hz to 1kHz |
DISP (Displacement) |
0.02 to 100mm EQ PEAK 3Hz to 500Hz 0.001 to 100mm EQ PEAK 10Hz to 500Hz |
Frequency range |
|
ACC (Acceleration) |
3Hz to 1kHz, 3Hz to 5kHz, 1Hz to 100Hz, 3Hz to 20kHz |
VEL (Velocity) |
10Hz to 1kHz, 3Hz to 1kHz |
DISP (Displacement) |
1Hz to 500Hz, 3Hz to 500Hz |
Measurement full-scale range |
|
For accelerometer PA-01 and accelerometers with sensitivity |
1.0 to 9.9mV/(m/s²) |
ACC (Acceleration) |
1, 10, 100, 1000m/s² |
VEL (Velocity) |
10, 100, 1000mm/s |
DISP (Displacement) |
0.1, 1, 10, 100mm |
Indication characteristics |
|
Acceleration |
RMS, EQ PEAK |
Velocity |
RMS, EQ PEAK |
Displacement |
RMS, EQ PEAK, EQ p-p |
Gain calibration (Accelerometer sensitivity selection establishes suitable gain) |
|
Setting range |
0.10 to 0.99, 1.0 to 9.9, 10 to 99mV (m/s²) |
Ambient conditions for operation |
|
Accelerometer |
-20 to +70℃, max. 90%RH |
Main unit |
-10 to +50℃, max. 90%RH |
Manual memory |
Maximum 99 data can be stored manually |
Auto memory |
Micro SD CARD |
Power requirements |
4 IEC R6 (size AA) batteries, AC adapter 6V (option) |
Battery life (continuous use) |
8 hours (approx.) |
Dimensions / Weight |
158(L) × 78(W) × 40(H)mm / 286g |
Supplied accessories |
Instruction manual, Battery,CD software, Micro-USB cable |