-
New Products
- Odor Sensing Meter
- Particle Counter/PM2.5 Air Quality Monitor
- Digital Earth Tester/ Solar Power Meter
- Thermo/Hygro/Barometer
- wind speed / wind volume / wind direction/ wind pressure
- Turbidity Meter/ pH/ORP/Temperature Meter
- Vibration Meter
- Coating Thickness Tester
- Brix Meter
- Light Meter
- Photosynthesis Light Quantum Meter/ Chroma Meter/ Luminance Meter
- Sound Level Meter
- CO Meter/ NDIR CO2 Meter
- Thermometer
- Infrared Thermometer
- Digital Tachometer
- HVAC Trms Clamp Meter
- ElectroMagnetic Field Tester/ Electrosmog Meter
- Power Analyzer
- Battery Capacity Tester
- Flexible AC Current Clamp
- Micro Ohmmeter
- Digital Multimeter
- Digital Insulation Tester
- Digital Earth Tester
- Digital Clamp Meter
- Multifunction Calibrator
- Lan Cablemeter
- Accessories
HVAC Trms Clamp Meter
AC 1000A Clamp Meter
- 10 in 1 multifunction clamp meter
- Voltage, Current, Power, Horse power, Reactive power, Apparent power, Phase angle, Frequency, Power factor, Phase sequence, Temperature, Resistance, Capacitance, Diode
- Trms reading/Dual display/Auto power off
ELECTRICAL SPECIFICATIONS (23℃±5℃)
AC Current (50Hz to 400Hz) : Trms
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
99.99A
|
10mA
|
±2% ±30dgts (50, 60Hz)
±4% ±30dgts (40~400Hz)
|
0.10A
|
1000A ac
|
999.9A
|
100mA
|
1.0A
|
ACA Inrush Current :
Range
|
Resolution
|
Sensitivity
|
Measurement Time
|
Overload Protection
|
99.99A
|
0.01A
|
>5A
|
100mS
|
1000A ac
|
999.9A
|
0.1A
|
>50A
|
mA Trms : (AC+DC) (Burden Voltage : 5mV/µA)
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
99.99mA
|
10nA
|
±1% ±30dgts
|
0.20µA
|
600V
|
999.9mA
|
100nA
|
2.0µA
|
AC Voltage (50Hz to 400Hz) : Trms
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
999.9mV
|
0.1mV
|
±1% ±30dgts (50, 60Hz)
±2% ±30dgts (40~400Hz)
|
2.0mV
|
600V ac
|
9.999V
|
1mV
|
0.020V
|
||
99.99V
|
10mV
|
0.20V
|
||
600.0V
|
100mV
|
2V
|
DC Voltage
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload Protection
|
999.9mV
|
0.1mV
|
±1.0% ±30dgts
|
2.0mV
|
600V
|
9.999V
|
1mV
|
0.020V
|
||
99.99V
|
10mV
|
0.20V
|
||
600.0V
|
100mV
|
2V
|
Resistance (Continuity<40Ω on the 999.9Ω range) :
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
999.9Ω
|
100mΩ
|
±1% ±10dgts
|
600V
|
9.999KΩ
|
1Ω
|
||
99.99KΩ
|
10Ω
|
||
999.9KΩ
|
100Ω
|
MΩ:
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
9.999MΩ
|
1KΩ
|
±5% ±10dgts
|
600V
|
99.99MΩ
|
10KΩ
|
3∅ Phase sequence indication :
Range
|
Frequency Response
|
Overload Protection
|
80V to 480V
|
50Hz / 60Hz
|
600V ac
|
Capacitance :
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
10.000μF
|
1nF
|
±1.5% ±5dgts
|
600V
|
100.00μF
|
10nF
|
||
1000.0μF
|
100nF
|
||
7000μF
|
1μF
|
±2.5% ±15dgts
|
Diode (Continuity<40mV) :
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
2.000V
|
1mV
|
±2% ±1dgt
|
600V
|
Temperature (K-Type ther mocouple) :
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
-50ºC to 900ºC
|
0.1ºC
|
±0.2% ±1ºC
|
30V ac or 60V dc
|
-58ºF to 1000ºF
|
0.1ºF
|
±0.2% ±2ºF
|
1f/3f TRUE Power (KW): (PF>0.5 or θ<60º )
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
99.99KW
|
10W
|
±5%rdg ±30dgts
(50, 60Hz)
|
600V ac / 1000A ac
|
600.0KW
|
100W
|
1∅/3∅ Horse Power (HP): (PF>0.5 or θ<60º )
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
99.99HP
|
0.01HP
|
±5%rdg ±30dgts
(50, 60Hz)
|
600V ac / 1000A ac
|
800.0HP
|
0.1HP
|
1∅/3∅Apparent Power :
Range | Resolution | Accuracy | Overload Protection |
99.99KVA | 10VA |
±2.5%rdg ±30dgts
|
600V ac/ 1000A ac |
600.0KVA | 100VA |
1∅/3∅Phase Angle : (50Hz, 60Hz)
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
-60° ~ 0° ~ +60°
|
0.1º
|
±6.0º
|
ACV>100V, ACA>10A
|
Frequency :
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
40Hz/1KHz
|
0.1Hz
|
±0.5%rdg ±2dgts
|
ACV>1.2V, ACA>6A
|
HVAC Application :
¨ Check current draw in motors and compressors.
¨ Use MAX/MIN/Recording in the temperature mode to assess efficiency.
¨ Test run/start capacitors.
¨ Confirm low voltage control signals.
¨ Measure flame safeguard device current draw.
¨ Confirm power sources
¨ Analyze temperature and power data with the aid of the time stamp.
¨ Insulation test up to 100MΩ.
Electrical Application :
¨ Check for energized circuits and balance loads.
¨1ψ/3ψ(3P3W/3P4W) Power analyzer.
¨ Evaluate electrical contacts.
¨ Capture inrush current readings of motor.
¨ Determine peak power demand periods.
¨ Verify line voltage stability.
¨ Monitor motors and other loads for excess heat.
¨ Check motor run/start capacitor values.
¨Check 3f phase sequence.