ElectroMagnetic Field Tester/ Electrosmog Meter

AC ELECTROSMOG METER (3 axis)
TES-593R

AC ELECTROSMOG METER (3 axis)

Product Features
  • Use rechargeable lithium-ion battery pack
  • Frequency range 10MHz to 8GHz.
  • 3 axis isotropic measurements of EMF.
  • Non-directional (isotropic) measurement with three-channel measurement probe.
  • High dynamic range.
  • Configurable alarm threshold and memory function.
  • LCD backlight function.
  • Easy & safety to use. APPLICATIONS:
  • High frequency (RF) electromagnetic wave field strength measurement.
  • Mobil phone base station antenna radiation power density measurement.
  • Wireless communication applications (CW, TDMA, GSM, DECT).
  • RF power measurement for transmitters.
  • Wireless LAN (Wi-Fi) detection, installation.
  • Spy camera, wireless bug finder.
  • Cellular/Cordless phone radiation safety level.
  • Microwave oven leakage detection.
  • Personal living environment EMF safety.

 

ELECTRICAL SPECIFICATIONS          

Sensor type
Electric field (E).
 
Frequency range
10MHz to 8GHz
 
Directional characteristic
Isotropic, 3-dimensional.
 
Measurement range (CW signal > 10MHz)
20mV/m to 108.0V/m ,
53μA/m to   286.4mA/m ,
W/m²  to 30.93W/m² ,
W/cm²  to 3.093mW/cm²
 
 
Dynamic range
Typical 75dB
 
Absolute error (@1V/m and 10MHz)
±1.0dB
 
Frequency response (taking into
  account typ. CAL
  factor)
±1.0dB (10MHz to 1.9GHz)
±2.4dB (1.9GHz to 8GHz)
 
 
Isotropy deviation
Typ. ±1.0dB for f >10MHz
 
Overload limit
10.61mW/cm² (200V/m)
 
Temperature response   (0 to 50)
±0.5dB
 
 
 
 
 
GENERAL SPECIFICATIONS

Measurement method

Digital, triaxial measurement

Measurement range selection

One continuous range

Display resolution

0.1mV/m, 0.1μA/m, 0.1μW/m², 0.001μW/cm²

Setting time

Typically 1s (0 to 90% of meas. value)

Display refresh rate

Typically 0.5 seconds

Display type

LCD 4 digit

Audible alarm

Buzzer

Measurement units

mV/m, V/m, μA/m, mA/m, μW/m²,

mW/m², W/m²,μW/cm², mW/cm²

Measurement display value

Instantaneous measured value, maximum value or maximum average value

Measurement alarm function

Adjustable threshold with ON/OFF

Measurement calibration factor CAL

Adjustable

Manual data memory and read storage

99 sets (only recall by meter)

Rechargeable lithium-ion battery

3.6V, 1940mAh

Charging time: Approx. 3 hours

Battery operation time

Approx. 10 hours

Dimensions

Approx. 67(W) x 60(T) x 247 (L)mm

Weight (including battery)

Approx. 250g

Accessories

Instruction manual, Rechargeable Lithium-ion battery, Carrying case, AC adaptor (DC 5V 1.5A)